![Ormandy Optimajor GLP S 3.0 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/ormandy/optimajor-glp-s-3-0/optimajor-glp-s-3-0_technical-and-maintenance-instructions_1653912015.webp)
Page
15 / 19
N
L1
T1
L1'
T2
L
A
G
O
E
C
O
T1
L1'
1
T2
N
L1
C
ONNECTION OF THE
L
AGO
E
CO REGULATOR ON THE
O
PTIMAJOR
GLP S
BOILERS RANGE
1.
Remove the right cap on the control panel and engage the regulator in this housing.
2.
Remove the 9 poles male connector with its 4 bridges on the back of the control panel, or remove the S.W.W.
priority Ventec module already connected.
3.
Connect the 9 poles connector (A) boiler side delivered with the regulator in the 9 poles female connector block
of the boiler and tighten the screws.
Connect the AMP 12 poles connector (B) delivered with the regulator in the AMP 12 poles plug of connector (A).
4.
Connect the 10 poles white connector on the connector block
II
of the regulator.
5.
Connect directly the following probes on the connector block
I
of the regulator.
- KFS : boiler probe
- SPFS : S.W.W. probe
6.
Connect the heating circulator to terminals 8 and 9 and if necessary the S.W.W. circulator to terminals 11 and 12
on the boiler 12 poles connector block ( back of the control panel ).
G
ENERAL
R
EMARKS
-
do not connect the summer / winter switch anymore, neither the S.W.W. tank thermostat, these functions being
ensured directly by the Lago Eco climatic regulator.
-
place the boiler thermostat instruction at 80°C approximately.
-
Connect the room thermostat on the Lago Eco.
10-poles connector
regulator side
9-poles connector (A)
boiler side
ConnectionkitLagoEcoregulator