42
PROBLEM
RESOLUTION
The lights inside the welding chamber do not
turn on.
• Check the light adjustment knob inside the weld
chamber and make sure it is not in the off posi-
tion. (Ref. Fig 4)
• Check the fuses.
Smoke created from the weld rises towards
the microscope and impairs vision of the
workpiece.
• The filter on the internal fan of the welding cham-
ber is too dirty.
• The fan is not working; check the fuse.
The shielding gas doesn’t flow when the
pedal is pushed.
• Check the home screen to verify the gas flow is
turned on.
• Check that the input pressure is not higher than 2
Bars.
• Check the flux regulator insidethe weld chamber.
• Verify that in gas tubing is not kinked or blocked.
I try to blow compressed air from the nozzle,
but no air comes out.
• Verify that in gas tubing in not kinked or blocked.
• Too low pressure.
The laser doesn’t turn on.
• Verify that the switch placed on the back is in ON
position.
• Verify that the emergency stop switch is released.
• Check the fuses.
• Verify the welder is plugged in to an active power
source.
When replacing fuses, ensure that the replacement fuse is of the same rating and same type. It is
always recommended to have a fuse installed when using this machine.
Contact Sunstone Engineering with any questions.
Содержание Combo 200
Страница 1: ...Orion Laser Welder User Manual Orion Combo 200 ...
Страница 4: ...4 ...
Страница 7: ...7 ...
Страница 52: ...52 ...