RGPS-92222GCP-NP Series User Manual
ORing Industrial Networking Corp.
54
Clear
Click to clear the counters for all ports
5.3.4 Loop Gourd
This feature prevents loop attack. When receiving loop packets, the port will be disabled
automatically,
preventing the loop attack from affecting other network devices.
Label
Description
Enable Loop Protection
Activate loop protection functions (as a whole)
Transmission Time
The interval between each loop protection PDU sent on each
port. The valid value is 1 to 10 seconds.
Shutdown Time
The period (in seconds) for which a port will be kept disabled
when a loop is detected (shutting down the port). The valid
value is 0 to 604800 seconds (7 days). A value of zero will
keep a port disabled permanently (until the device is
restarted).
Label
Description
Port
Switch port number
Enable
Activate loop protection functions (as a whole)
Action
Configures the action to take when a loop is detected. Valid values include
Shutdown Port
,
Shutdown Port
, and
Log or Log Only
.