RGPS-92222GCP-NP Series User Manual
ORing Industrial Networking Corp.
19
Label
Description
Redundant
Ring
Check to enable O-Ring topology.
Ring Master
Only one ring master
is allowed in a ring. However, if more
than one switch are set to enable
Ring Master
, the switch with
the lowest MAC address will be the active ring master and the
others will be backup masters.
1
st
Ring Port
The primary port when the switch is ring master
2
nd
Ring Port
The backup port when the switch is ring master
Coupling Ring
Check to enable
Coupling Ring
.
Coupling Ring
can divide a
big ring into two smaller rings to avoid network topology
changes affecting all switches. It is a good method for
connecting two rings.
Coupling Port
Ports for connecting multiple rings. A coupling ring needs four
switches to build an active and a backup link.
Links formed by the coupling ports will run in active/backup
mode.
Dual Homing
Check to enable
Dual Homing
. When
Dual Homing
is
enabled, the ring will be connected to normal switches through
two RSTP links (ex: backbone Switch). The two links work in
active/backup mode, and connect each ring to the normal
switches in RSTP mode.
Apply
Click to apply the configurations.
Note:
due to heavy loading, setting one switch as ring master and coupling ring at the same
time is not recommended.