9600-GB ERSTANBAU (352)
FIRST-TIME CONNECTION TO TRACTOR
GB
- F
34
-
Power supply
Required fitting to tractor
•
3-pole power socket
-
Fix accompanying 3-pole power socket to
the rear of the tractor
-
Power supply through a relay (9)
Relay is connected to the ignition switch (10).
-
Conductor diameter at least 2,5 mm
2
-
Fuse 16A (11)
This conversion is to be made
only by a specialist.
Do not connect directly to ignition
switch (danger of fire or damage
to electrical unit).
Use only recommended-strength
fuses as the use of stronger fuses
will destroy the electrical unit!
Establishing the connection to tractor
-
After completion of the work as shown, plug the 3-pole plugs into the tractor's
power sockets.
-
Check that lights are functioning.
3-POL.
TD 48/96/22
1
12V=
+
-
8
11
9
3-POL
"15/30"
"31"
10
12
TD 48/96/21
86
86a
87
85
30
TD 48/96/23
L
Installation of control panel
- Install the accompanying splicing plate (L) into tractor cabin so that it is within the driver’s
sight and reach.
- Insert control panel (1) in splicing plate.