Method of control via Modbus protocol
−8−
STEP 4
Cycle the power
Parameters for "communication parity," "communication stop bit" and "transmission waiting time" will be enabled
after the power is cycled.
STEP 5
Operate the motor
1.
Set the rotation speed using the
internal potentiometer.
2.
Turn the NET-IN3 (FWD) of "driver
input command" in operation
commands ON, and then write to the
holding register.
3.
Confirm that the motor
rotates without problem.
Programmable controller
or master device
Or
STEP 6
Were you able to operate the motor properly?
How did it go? Were you able to operate the motor properly? If the motor does not function, check the following
points:
•
Is any alarm present?
•
Are the power supply, motor and RS-485 communication cable connected securely?
•
Are the slave address, transmission rate and termination resistor set correctly?
•
Is the C-ERR LED lit?
•
Is the C-DAT LED lit?
For more detailed settings and functions, refer to the following pages.