Guidance
46
JOG operation
Constant speed operation can be performed with JOG operation. The motor operates continuously while the FW-JOG
input or RV-JOG input is being ON.
1. Turn on the control power supply (24 VDC) and main power supply.
The READY output and PLS-RDY output will turn ON.
2. Check the READY output has been turned ON and turn the FW-JOG input or RV-JOG input ON.
The motor will start operation.
When the FW-JOG input is turned ON, the motor rotates in the forward direction, and when the RV-JOG input is
turned ON, the motor rotates in the reverse direction.
3. Turn the input signal OFF.
The motor will decelerate to a stop. When the motor stops, the READY output will turn ON.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Motor operation
Control power supply (24 VDC)
Main power supply
FW-JOG input or
RV-JOG input
PLS-RDY output
READY output
ON
OFF
IN-POS output
ON
OFF
MOVE output
1
2
3
2
1