Guidance
43
10-6 Timing
chart
This section shows ON/OFF timings for input signals and output signals.
For details, check with the
AZ
Series Function Edition.
Positioning operation
Built-in controller type
Positioning operation can be performed with selecting the operation data.
1. Turn on the control power supply (24 VDC) and main power supply.
The READY output will turn ON.
2. Check the READY output is turned ON and turn the START input ON by selecting the operation data number with
the M0 to M2 outputs.
The motor starts positioning operation.
3. Check the READY output has been turned OFF and turn the START input OFF.
When the operation is complete, the READY output will turn ON.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Motor operation
Control power supply (24 VDC)
Main power supply
ON
OFF
MOVE output
M0 to M2 input
START input
READY output
ON
OFF
IN-POS output
1
1
2
3
3