Guidance
39
Description of JOG operation switches
Switch
Description
Performs continuous operation in the negative direction at the operating speed set in the "(JOG)
Operating speed (high)" parameter.
Performs continuous operation in the negative direction at the operating speed set in the "(JOG)
Operating speed" parameter.
Performs positioning operation in the negative direction for the travel amount set in the
"minimum travel amount" of the JOG operation switches.
Stops the operation immediately.
Performs positioning operation in the positive direction for the travel amount set in the
"minimum travel amount" of the JOG operation switches.
Performs continuous operation in the positive direction at the operating speed set in the "(JOG)
Operating speed" parameter.
Performs continuous operation in the positive direction at the operating speed set in the "(JOG)
Operating speed (high)" parameter.
If the motor does not operate even when clicking the JOG operation switches, check the following points.
· Are the power supply, motor, and
MEXE02
connected properly?
· Is an alarm present?
When changing the operating condition of JOG operation
1. Click on “Motor & Mechanism(Coordinates/JOG/Home Operation)” under “Parameter,” in the left side of the screen.
The “Motor & mechanism” parameter window appears.
2. Change the "JOG/HOME/ZHOME operation setting" parameter to "manual setting."
3. Change the operating condition using following fi ve parameters.
4. After changing the operating condition, click the [Writing data] icon in the toolbar to download to the driver.