Setting
31
9 Setting
This chapter explains how to set the motor and driver functions.
9-1
Setting of the built-in controller type and pulse input type with RS-
485 communication interface
The fi gure shows the built-in controller type driver.
SW1
Function setting switch (SW1)
No.2: Sets the protocol.
No.1: Sets the address number (slave address).
Address number setting switch (ID)
Transmission rate setting switch (BAUD)
Termination resistor setting switch (TERM.)
ON
Be sure to turn off the driver power before setting the function setting switch (SW1). The new setting
of the SW1 will become eff ective after the power is cycled.
About resolution
The initial value of resolution of the driver is 1000 P/R. The initial value of resolution may vary depending on the
product connected. Check with the operating manual of the motor or motorized actuator used.
Protocol
Set the protocol of RS-485 communication using the SW1-No.2 of the function setting switch.
Factory setting
Built-in controller type; OFF
Pulse input type with RS-485 communication interface; ON
SW1-No.2
Protocol
ON
Modbus RTU mode
OFF
Connecting with network converter