Installation
8
4
Installation
This chapter explains the installation location and installation methods of the
NETC01-M2
.
The installation and wiring methods in compliance with the EMC Directive are also explained.
4-1
Location for installation
The
NETC01-M2
has been designed and manufactured for use as a component to be installed inside equipment.
Install it in a well-ventilated location that provides easy access for inspection. The location must also satisfy the
following conditions:
•
Inside an enclosure that is installed indoors (provide vent holes)
•
Operating ambient temperature 0 to +40 °C (+32 to +104 °F) (non-freezing)
•
Operating ambient humidity 85% or less (non-condensing)
•
Area that is free of explosive atmosphere or toxic gas (such as sulfuric gas) or liquid
•
Area not exposed to direct sun
•
Area free of excessive amount of dust, iron particles or the like
•
Area not subject to splashing water (rain, water droplets), oil (oil droplets) or other liquids
•
Area free of excessive salt
•
Area not subject to continuous vibration or excessive shocks
•
Area free of excessive electromagnetic noise (from welders, power machinery, etc.)
•
Area free of radioactive materials, magnetic fields or vacuum
4-2
Installation method
Install the
NETC01-M2
to a 35 mm (1.38 in.) width DIN rail.
There must be a clearance of at least 50 mm (1.97 in.) in the horizontal
and vertical directions, between the
NETC01-M2
and enclosure or
other equipment within the enclosure.
When installing two or more
NETC01-M2
in parallel, it is possible to
install them closely in the horizontal direction. Provide a minimum
clearance of 50 mm (1.97 in.) in the vertical direction.
50 mm (1.97 in.)
or more
50 mm (1.97 in.)
or more
Be sure to install the
NETC01-M2
vertically (vertical
position). If the
NETC01-M2
is installed in the direction
other than vertical position, its heat radiation effect will
deteriorate.
Mounting to DIN rail
Pull down the DIN lever of the
NETC01-M2
and lock it. Hang the hook at the rear to the DIN rail, and push in the
NETC01-M2
. After installation, secure the both sides of the
NETC01-M2
with the end plate.
Hook
DIN rail
DIN lever
End plate