Operation using the OPX-2A
45
13 Operation using the
OPX-2A
This chapter explains the overview and operation using the
OPX-2A
.
13-1
Overview of the
OPX-2A
The
OPX-2A
is a data setter that lets you set parameters and monitor the communication time.
In addition, the
OPX-2A
can be used to save the data of
NETC01-M2
. There are four destinations (data banks) to
save data.
OPX-2A
Data bank 1
Data bank 0
Data bank 2
Data bank 3
NETC01-M2
NETC01-M2
Set parameters.
Up to 4 sets of parameters
can be saved.
Copy one set to the
NETC01-M2
.
The
OPX-2A
can be used for the following purposes:
•
The parameters for the
NETC01-M2
can be set.
•
The communication time and status can be monitored.
•
The alarm records can be checked and cleared.
•
The parameters set in the
NETC01-M2
can be saved to the
OPX-2A
.
•
The parameters saved in the
OPX-2A
can be copied to another
NETC01-M2
connected to the
OPX-2A
.
Edit lock function
Enable the edit lock function if you want to prevent parameters from being edited or cleared. Parameters cannot be
changed or deleted while the edit lock function is enabled.
z
Setting the edit lock function
In the top screen of each operation mode, press the
key for at least
5 seconds.
The display will show “LocK” and the edit lock function will be enabled.
The “LOCK” LED in the LED indicator area will also be lit.
“LOCK” lit
z
Canceling the edit lock function
Again in the top screen of each operation mode, press the
key for at
least 5 seconds.
The display will show “UnLocK” and the edit lock function will be cancelled.
The “LOCK” LED in the LED indicator area will turn off.
“LOCK” off