Details of command
38
When an error has occurred (remote register)
1. Specify the register address number.
2. Check the register address number response.
3. Turn the TRIG from OFF to ON. The selected parameter or operation data is started writing.
4. When the written value is an error, the STATUS is turned from OFF to ON. Check the command code and DATA.
5. Turn the TRIG from ON to OFF, and reset the error status.
If an error has occurred in data transfer, the STATUS is turned ON.
When specifying data that is outside the setting range (write 1,000 to the “STOP input action”
parameter)
TRIG
0001h
0001h
0 s or more
0 s or more
0 s or more
1100h
1,000 (03E8h)
1100h
1,000 (03E8h)
OFF
ON
TRIG_R
OFF
ON
STATUS
OFF
ON
Command code
Register address number
response
Command code response
DATA response
DATA
Register address number
[
NETC01-M2
to master]
[Master to
NETC01-M2
]
(TM+TS)×2
(TM+TS)×2
(TM+TS)×2