| Operating instructions
SERVICE AND TROUBLESHOOTING
1. Switch on the "Internal printer" button.
The button for paper feed is activated.
2. Open printer hood and cover of the printer.
3. Remove empty paper sleeve with the axis. Remove any paper present in the printer by
pressing the button on the printer (line advance). Do not pull on the paper here!
4. Slide a new paper roll onto the axis and insert it into the cut-out of the housing
provided for mounting the axis so that the axis audibly engages.
Attach paper roll in such a way that the paper rolls off toward the back.
Attach axis as shown on the sticker in the paper compartment.
5. Cut off paper start straight and insert it into the printer.
6. Move paper forward by pressing the line advance button. Paper is not to be pulled through by hand!
7. Guide paper through the slot in the cover and close cover again.
Changing an ink ribbon
1. After changing the cover, push the part of the ink ribbon cassette marked "PUSH"
The ink ribbon comes out of the drive shaft on the opposite side.
2. Remove ink ribbon from above.
3. Using the rotary knob (see arrow for rotation direction) which protrudes on one side,
tighten the external part of the new ink ribbon and insert cartridge into the printer.
4. Insert free end of the ink ribbon into the slot through which the paper is also led out.
The paper is guided between the ink ribbon cartridge and the free end of the ink ribbon.
5. Tighten ink ribbon again if necessary and close printer hood.
9.1.5
Printing a test page
X
Press "Print test page" button.
A test page with a mixed character set is output on the printer which has been activated (internal or external).
9.1.6
Service screen
View current status of all digital or analog input and output signals of the control computer.
•
Digital In: Current values of the digital inputs of the computer
•
Digital Out: Current values of the digital outputs of the computer
•
Analog In: Current values of the analog inputs of the computer
•
Analog Out: Current values of the analog outputs of the computer
•
Inverter: Status of the serial interface used for communication between computer and power source (RS232)
•
Actual Val: Display of the current actual value of the running process calculated from the information of the analog
inputs or serial inverter interface
1. Press "Service Screen" button.
The following display appears:
Fig. 39: Service Screen