48 |
orbitalum tools
GmbH, D-78224 Singen, www.orbitalum.com, Tel. +49 (0) 77 31 792-0
(01.2012) OM_BA_ORBIMAT_CA_01_EN
OPERATION
ORBIMAT CA
| Operating instructions
8.8.2
Connecting and configuring the BUP control unit
The control unit does not have its own power supply: It is connected to the machine via the connection socket and is
thus ready for operation.
Connecting the unit
1. Connect unit to the "BUP Control" connection socket of the machine.
2. In the main menu, select "System settings" > "System adjustments".
3. Select the "Yes" option for "External input for abort".
The signal from the oxygen meter is monitored continuously.
To save the activation of the external input in a procedure:
X
Save procedure after activation.
Activating the unit
1. In the main menu, select "Manual/Adjust programming" > "Adjust parameters" > "Gas settings".
2. Select the "Yes" option for "Backup gas control".
The parameters required for programming the BUP unit are enabled.
Programming the values and reference values for the individual parameters
See operating instructions of supplemental unit.
Required software version for BUP control unit:
At least version 0.1.08 from September 2007
Is there an older software version on the machine?
X
Update the software.
8.8.3
TIG manual welding torch
Water-cooled manual welding torches with the ORBIMATIC connection system can be connected.
The torch should have a torch button for starting the process.
•
For cassette weld heads: Ground wire required.
•
For LP heads: The included ground wire can also be used in conjunction with the manual welding torch.
Procedures can be adjusted and saved for manual operation.
Functions in manual operation:
Torch button on manual torch
The torch button functions in four-cycle operation:
•
Start process by pressing the button.
•
During the welding process, press the torch button again and hold it down: The machine carries out final slope-off
for the programmed time and as long as the torch button is pressed. When the final current is reached, the machine
ends welding automatically.
•
Release torch button while slope-off is active: The process is interrupted. (Used to set a tack point without having
to wait for the entire slope-off time to pass, for example.) Weld current and pulse times
Weld current and pulse times
As programmed in sector 1: The machine remains in sector 1 during the entire manual welding procedure; any program-
med sector times and rotation angles are meaningless.
Gas pre purge, ignition current, slope-off and gas post purge
: As programmed
Sensors for gas and water monitoring
: Active during manual operation, weld current is monitored.
Speed monitoring
: Deactivated; programmed weld speeds are meaningless.
Selecting a weld head type
1. In the main menu, select "Manual/Adjust programming" > "Parameter adjustments" > "Basic adjustments".
2. Select and highlight the "Weld head model" field.
The list of weld head models appears in the display: