9 Clamping wedge and mandrel assembly BRB 4
Operating instructions BRB
56
(08.10)
MT_BRB_BA_04_790086762_00.doc
orbitalum tools
gmbh
9.5.3
Removing the mandrel:
BRB 4 "NC" Auto with mandrel Ø 19.05 and Ø 34.50
1. Set the rotary tensioning switch (1) to the unclamped position
(see chap. 10.1.3, p. 61).
2. Remove the clamping wedges (see chap. 8.3.2, p. 34 and chap. 9.3.3,
p. 50).
3. Pull the clamping wedge attachment (2) out of the mandrel (3).
4. Loosen PU hose (4) by pressing the washers on the two angle screws (5).
5. Loosen cylinder screw (6) on clamping cylinder (7) until the clamping
cylinder rotates.
6. Rotate the clamping cylinder (7) down from the mandrel (3).
7. Loosen headless screw (8) on sleeve (9).
8. Push the sleeve (9) down from the mandrel (3).
9. Mandrel dia. 19.05: remove the tool mounting plate (10).
10 Move the mandrel (3) in the direction of the arrow with the locking wheel
(11).
11. Pull mandrel (3) out of the housing (12).
12
6
9
5
7
11
8
4
5
2
3
10
1