Operating instructions BRB
8 Clamping wedge and mandrel assembly BRB 2
orbitalum tools
gmbh
(08.10)
MT_BRB_BA_04_790086762_00.doc
31
8.2.2
Replacing the clamping wedges:
BRB 2 "standard" with mandrel Ø 19.05
1. Remove star knob (1).
BRB 2 Pneumatic/Auto, remove ball-head grip (6).
BRB 2 "standard" Pneumatic und
BRB 2 "standard" Pneumatic/Auto
BRB 2 "standard" Electric
2. Push threaded spindle (2) out of mandrel (3) in direction of arrow.
3. Detach clamping wedges (4) from clamping disc (5) and push them down
and off the threaded spindle (2).
4. Push selected clamping wedges over threaded spindle (2) and insert them
in the clamping disc (5).
5. Push the threaded spindle with clamping wedges back into the mandrel.
6. Push clamping wedges (4) into the mandrel groove.
7. Refit star knob (1).
BRB 2 Pneumatic/Auto, refit ball-head grip (6).
1
6
2
3
5
4
2