MNL940-677-000  

 

 

 

REV - B   

 

 

 

3/20/2017 

 

3

 

1.1 

SPECIFICATIONS

   

 

INPUTS 

 

MODEL

 

DC INPUT

 

DC BURDEN (full load)

 

DC BURDEN (no load)

 

INV-1200 - 250

 

250 VDC +/- 20%

 

7.5 AMPS @ 200 VDC

 

270 mA   +/- 20%

 

INV-1200 - 125

 

125 DC +/- 20 % 

 

15 AMPS @ 100 VDC

 

550 mA  +/- 20%

 

INV-1200 - 48

 

48 VDC +/- 20 %

 

40 AMPS DC @ 38 VDC

 

1.7 A +/- 20%

 

 

OUTPUT 

 
Power:   

1200 Watts 

 
Voltage: 

120 VAC +/-2% 60 Hz (available @ 50 and 400 Hertz). Fre/- 0.1% 

 

 

(220-240V output available with external transformer option. See option info.) 

 
Current: 

10 amps RMS continuous (30 amps peaks)  

 
Waveform: 

Sine wave with less than 3% T.H.D. (linear load) 

 
Efficiency: 

80- 85% typical @ full load. 

 

AC INPUT*

 

*Optional bypass mode only. 130 VAC max @ 10 amps (fuse) see text. 

 

 

PROTECTION

 

 
Input:   

DC circuit breakers (optional AC line bypass input has 10 amp fuse) 

 
Output:  

Electronic over current protected. 

 

 

Thermal: 

Thermal cut-out that monitors temperature. Shuts down during over-temp conditions. 
Automatic Reset. 

 

MECHANICAL

   

WIDTH: 17 in. (43.2cm) (19” standard EIA rack panel) 

 

 

 

LENGTH: 17in. (48.3cm) 

 

 

 

HEIGHT: 3.5in. (14.4cm) 

 

 

 

WEIGHT: 25Lbs. (11.3kgs) 

 

ENVIRONMENTAL

 

 Operating temperature -20

°

C to +55

°

C, 95% RH non – condensing. 

 

OPTIONS:

 

A1- AC preferred option. Applies supplied line to the inverter output terminals under 
normal conditions. If the AC line is lost, the inverter output will automatically be switched 
to the output terminals to supply the load. 

 
 

D1- DC preferred option.  Inverter supplies load from the DC source under normal 
conditions. If the DC source or inverter fails, the AC line will automatically be switched to 
the output terminals to supply the load. 

 
 

I = Transformer option. Provides 220-240VAC output at 50 or 60Hz. This option requires 
an additional 2U chassis. 

 

 

 
TB = Substitutes rear panel terminal block for NEMA 5-15R receptacles.  

Available with all variants. 
 

 

Содержание Behlman INV-1200 Series

Страница 1: ...T BEHLMAN CUSTOMER SERVICE DEPARTMENT PHONE TOLL FREE 1 800 874 6727 EMAIL SERVICE BEHLMAN COM WEB WWW BEHLMAN COM OR WRITE BEHLMAN CUSTOMER SERVICE DEPARTMENT 80 CABOT COURT HAUPPAUGE NY 11788 PHONE...

Страница 2: ...the presence of flammable gases or fumes Operation of any electrical instrument in such an environment constitutes a definite safety hazard KEEP AWAY FROM LIVE CIRCUITS Operating personnel must not re...

Страница 3: ...us conditions due to the exposure of hazardous voltage that can be lethal if contacted Neither Behlman Electronics Hauppauge NY USA nor any of the subsidiary sales organizations can accept any respons...

Страница 4: ...be refused the customer being liable for all shipping handling and repair costs When packing for reshipment use the original shock absorbent material and shipping container to preclude damage to the...

Страница 5: ...ial Authorization RMA number This number must be attached to the equipment sent back for warranty repair Equipment must be shipped back to Behlman prepaid No collect shipments will be accepted Behlman...

Страница 6: ...arm Contacts 2 4 Optional Step up Transformer 3 0 OPERATING INSTRUCTIONS 3 1 Controls and Indicators 3 2 Optional Alarm Contacts 3 3 Operational Considerations Load Limitations Powering Reactive Loads...

Страница 7: ...gged steel enclosure making them well suited to operation in industrial applications Available options include an AC input bypass and signaling contacts The AC bypass option is available in two config...

Страница 8: ...protected Thermal Thermal cut out that monitors temperature Shuts down during over temp conditions Automatic Reset MECHANICAL WIDTH 17 in 43 2cm 19 standard EIA rack panel LENGTH 17in 48 3cm HEIGHT 3...

Страница 9: ...nt the inverter by the mounting ears only If the unit is intended for use in a mobile or other high vibration application the use of additional support for the rear of the chassis is highly recommende...

Страница 10: ...with respect to earth This situation does not meet the requirements of NEC section 250 regarding separately derived AC source To allow compliance with NEC rules an additional common terminal is provi...

Страница 11: ...MNL940 677 000 REV B 3 20 2017 6 FIGURE 2 2 INV1200 WIRING WITH BYPASS OPTION FIGURE 2 3 INV1200 WIRING WITH BYPASS AND TB OPTIONS...

Страница 12: ...t Each function provides one set of dry form C contacts which accommodates any logic required The internal relays will change state if any of the three voltages are outside of limits required to provi...

Страница 13: ...standard 120VAC output to the higher value In addition the bypass option can also be included with the external transformer A block diagram of the optional transformer configurations is provided in fi...

Страница 14: ...ion provides a terminal block 6 AC LINE INPUT TERMINALS Screw type terminal block provided with alarm bypass option For connection to bypass source 7 FAN EXHAUST Heated air exhaust Minimum 4 inch clea...

Страница 15: ...e sound of the cooling fans should be evident 3 The appropriate front panel LEDs should be illuminated 4 To test the inverter use a True RMS type meter to confirm the output voltage is as specified 5...

Страница 16: ...s the INV 1200 series to start most high in rush loads in its power range It must be understood that the DC power source suppling the inverter must also have this capability in order to derive these b...

Страница 17: ...bridge rectifier followed by a capacitive filter the current waveform associated with this circuit is illustrated below in figure 3 3 The input current to this type of circuit is drawn in large gulps...

Страница 18: ...at the output that contains the original sine wave information The 20 KHz carrier frequency is removed by a low pass LC filter This provides an amplified version of the original modulation signal to...

Страница 19: ...in inverter Check polarity if ok the unit may have an internal fault Return for service WARNING Service of this device requires specialized equipment and trained personnel There are no internal user...

Страница 20: ...MNL940 677 000 REV B 3 20 2017 15 5 0 MECHANICAL OUTLINE ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED...

Страница 21: ...EV B 3 20 2017 16 REVISION HISTORY Rev ECO DESCRIPTION DATE N A INV 1200 Gen 2 Initial Release 9 16 2016 A 17 030 Revised specification figure 2 1 to 2 3 redrawn 2 28 17 B 17 032 Corrected text figure...

Отзывы: