CALORAMA/COMFORT VIEW (CCV) SERIES HEATER SPECIFICATIONS
Model
Maximum input BTU/h (KW)
Minimum input BTU/h (KW)
NATURAL GAS
Manifold Gas Pressure:
Minimum Gas Supply Pressure
Maximum Gas Supply Pressure
PROPANE/LP GAS *
Manifold Gas Pressure:
Minimum Gas Supply Pressure
Maximum Gas Supply Pressure
Gas Inlet Connection
Minimum Wall Thickness
Maximum Wall Thickness
Vent Opening Diameter in Wall
Height of Unit
Width of Unit
Depth of Unit (including wall
mounting Plate)
8 000 (2,32) 15 000 (4,40) 20 000 (5,86)
4 100 (1,20) 6 900 (2,00) 9 500 (2,78)
4" (102 mm) wc 4" (102 mm) wc 4" (102 mm) wc
5" (127 mm) wc 5" (127 mm) wc 5" (127 mm) wc
7" (178 mm) wc 7" (178 mm) wc 7" (178 mm) wc
10" (254 mm) wc 10" (254 mm) wc 10" (254 mm) wc
11" (279 mm) wc 11" (279 mm) wc 11" (279 mm) wc
13 " (330 mm) wc 13" (330 mm) wc 13" (330 mm) wc
3/8" NPT 3/8" NPT 3/8" NPT
2" (51 mm) 2" (51 mm) 2" (51 mm)
12" (305 mm) 12" (305 mm) 12" (305 mm)
8,31" (211 mm) 8,31" (211 mm) 8,31" (211 mm)
23,23" (590 mm) 23,23" (590 mm) 23,23" (590 mm)
13,78" (350 mm) 19,69" (500 mm) 27,56" (700 mm)
7,64" (194 mm) 7,87" (200 mm) 8,27" (210 mm)
Note: Minimum gas inlet gas pressure is for purpose of input adjustment.
* Exterior Regulator pressure MUST NOT EXCEED 13 IN. W.C.
CCVI
Calorama/Comfort
View I
CCVII
Calorama/Comfort
View II
CCVIII
Calorama/Comfort
View III
WARNING:
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY
DAMAGE: REFER TO THIS MANUAL. FOR ASSISTANCE OR
ADDITIONAL INFORMATION, CONSULT A QUALIFIED INSTALLER,
SERVICE AGENCY OR YOUR GAS SUPPLIER.