23
SYMPTOM
Room will not maintain
temperature.
POSSIBLE CAUSE
7. Improper gas supply.
1. Thermostat adjusted wrong .
2. Heater is too small for the
heated space.
3. Excessive air leaks in room.
4. Broken or damaged thermostat
bulb assembly.
5. Insufficient gas supply.
SOLUTION
7. Call your gas supplier.
1. Adjust thermostat to "HI"
position and modulate down
until a proper room
temperature rate is attained.
2. Average room size heating
capacity:
UNIT Ave. Floor Area Capacity
CCV I up to 200 Sq Ft
CCV II up to 400 Sq Ft
CCV III up to 500 Sq Ft
Obtain proper unit(s) for area
to be heated.
3. Adequately close off and
insulate your room to
eliminate heat loss.
4. Replace Gas Control Valve.
5. Call your gas supplier.