SAFETY INFORMATION FOR USERS OF PROPANE / L.P. GAS:

Propane/L.P. gas is highly flammable gas that can cause fire and explosions. Propane/L.P. 
gas is naturally odorless, but a special odorant is added to the gas to alert you to the 
presence of a gas leak, should one occur. This odor may fade over time. It is recommended 
that you obtain a "Scratch and Sniff" brochure to familiarize occupants with the odor 
associated with propane/LP gas. Not everyone is familiar with the safety precautions 
covering the use of Propane/L.P. gas. These precautions will help you safeguard your 
family and your property from an accident. Read the following carefully and make sure 
that everyone in your household knows the correct action to take in the event of a leak 
in the Propane/L.P. gas system.

PROPANE / L.P. GAS ODOR WARNING 

The odorant put into the Propane/L.P. gas by your gas supplier will allow you to detect 
the distinctive smell of gas in the event of a leak. If you smell propane / L.P gas anywhere 
in or around your house or apartment, this odor indicates it is time to take immediate 
action in order to reduce or eliminate the risk of injury and or property damage.  

KNOW AND MAKE SURE OTHERS IN YOUR HOUSEHOLD KNOW THE FOLLOWING 
PROCEDURES TO TAKE IN THE EVENT OF A PROPANE / L.P. GAS LEAK:

1. DO NOT operate electric switches, light matches, or use your telephone.  Do not do 
anything that could create an open flame or sparks, resulting in the ignition of leaking gas.

2. USE a neighbor’s telephone and call a qualified Propane / L.P. gas service technician 
or the gas supplier AND the fire department.  Even if the odor of Propane / L.P. gas fades
 and you cannot detect the smell of gas, DO NOT turn on any appliances.  

3. DO NOT re-enter the building or area until it has been declared safe to enter by the 
fire department or other authority. A properly trained and qualified Propane / L.P. gas 
service technician or gas supplier must repair the system leak and then re-light your gas 
appliances for you.

WARNING:  DO NOT USE THIS HEATER IF ANY PART HAS BEEN UNDER WATER.  

IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE APPLIANCE 

AND TO REPLACE ANY PART OF THE CONTROL SYSTEM 

AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER.

IF YOU DO NOT UNDERSTAND THIS INFORMATION OR FEEL YOU NEED 

ADDITIONAL INFORMATION, CONTACT YOUR GAS SUPPLIER.

Содержание CALORAMA

Страница 1: ...ORTED BY The Gas Appliance Company Inc FLORIDA US of A www orbisheat com WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage person...

Страница 2: ...Installation Figure 6 Exploded Side View of Vent Installation Vent and Wall Plate Installation Figure 7 Vent Kit Assembly Figure 8 Vent Cap as seen from the Outside Connect Gas Piping Gas Supply Press...

Страница 3: ...rect Vent Wall Furnace Standard CAN 2 32M98 to provide safe trouble free operation throughout the expected life of the unit Any alteration modification or adjustment not specifically mentioned in this...

Страница 4: ...the vent assembly supplied with the unit so that harmful gases will not gather inside of the building The vent kit part number for your unit can be found in the exploded parts view at the end of this...

Страница 5: ...e immediate action in order to reduce or eliminate the risk of injury and or property damage KNOW AND MAKE SURE OTHERS IN YOUR HOUSEHOLD KNOW THE FOLLOWING PROCEDURES TO TAKE IN THE EVENT OF A PROPANE...

Страница 6: ...mm wc 7 178 mm wc 10 254 mm wc 10 254 mm wc 10 254 mm wc 11 279 mm wc 11 279 mm wc 11 279 mm wc 13 330 mm wc 13 330 mm wc 13 330 mm wc 3 8 NPT 3 8 NPT 3 8 NPT 2 51 mm 2 51 mm 2 51 mm 12 305 mm 12 305...

Страница 7: ...osing a location for your ORBIS Calorama Comfort View Series Direct Vent Wall Furnace please remember that the Vent Kit supplied with the unit must be installed WITHOUT alteration with the exception o...

Страница 8: ...sure regulator provided with this unit C 12 in minimum 12 in minimum 4 ft minimum 4 ft minimum 12 in minimum 3 ft minimum Grade Forced air inlet Mechanical draft vent terminal see 7 8 b Mechanical dra...

Страница 9: ...3 The template illustrates all of the openings and mounting holes and their correct location for EACH UNIT The illustration Figure 3 gives you the required dimensional information for mounting the uni...

Страница 10: ...shed unit to adjacent combustible materials Figure 3 ALL MODELS Unit Mounting Instructions 8 35 212 mm 1 65 42 mm 11 89 302 mm 12 09 307 mm 10 85 275 5 mm 14 78 375 5mm 7 89 200 5 mm 4 8 121 9 mm 5 12...

Страница 11: ...10 Figure 4 Unit Mounting Template Position Figure 5 Wall Mounting Plate ALL MODELS Unit mounting positions Wall mounting positions TEMPLATE...

Страница 12: ...ombustion and ventilation air must NEVER be obstructed Prepare for Installation After ensuring that the location you have selected for the installation complies with the requirements outlined in this...

Страница 13: ...rotection pipe to pass through without bending In addition make sure that the holes in the inside and outside wall are concentric to one another NOTE Cut the outside hole slightly lower not more than...

Страница 14: ...he vent cap is securely engaged with the similar sized opening in the rear of the unit Make sure the exhaust vent pipe remains engaged in its position in the vent cap The air inlet pipe must also slid...

Страница 15: ...ust be installed in accordance with all applicable building and plumbing codes For Propane Units Gas supply Line Pressure MUST NOT EXCEED 13 IN W C It is recommended that a gas shut off valve be insta...

Страница 16: ...e bubbles to form Note any leaks in the piping system Shut off the gas at the shut off valve if installed or at the gas meter of the Propane LP tank serving the structure Fix the leaking joint and re...

Страница 17: ...in or turn by hand don t try to repair it call qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Im...

Страница 18: ...the most comfort for you Excessively high temperature settings can cause you to constantly readjust the thermostat and lose valuable efficiency WARNING DO NOT OPERATE THIS APPLIANCE WITH THE PILOT MA...

Страница 19: ...he back cover Step 4 Carefully examine the interior of the vent pipe If you notice any blockage or obstruction that was not part of the unit when it was installed clean the pipes and prepare them for...

Страница 20: ...k on the wall mounting plate Step 8 Reconnect the gas supply Perform the leak test procedure found in the section of this manual titled Check for Gas Leaks on page 14 Step 9 Verify Proper Operation Af...

Страница 21: ...d of the front cover leaning about an inch forward push the front cover in and down until the bolts lock into place Slide the overhangs at the upper end of the front cover under the back cover and fix...

Страница 22: ...is damaged or wire lead is loose 3 Pilot orifice is clogged 4 Gas Control knob not set properly 5 Improper gas supply SOLUTION 1 No action required will stop after a short period of operation 2 Apply...

Страница 23: ...that position is in the center of the pilot flame tip Replace as necessary 3 Wait 5 minutes to allow the heater to cool down then relight 1 Review correct lighting procedures see Figure 10 on page 15...

Страница 24: ...as supply SOLUTION 7 Call your gas supplier 1 Adjust thermostat to HI position and modulate down until a proper room temperature rate is attained 2 Average room size heating capacity UNIT Ave Floor Ar...

Страница 25: ...24 SECTION VI REPLACEMENT PARTS GUIDE Orbis Calorama Comfort View Series Gas System 2 15 1 3 6 7 8 4 5 9 10 11 12 14 1 A B C D E F 13...

Страница 26: ...n Burner Injector CCV III L P 1 35mm CCV 3004P 5 Main Burner Injector Adaptor CCV 5005 6 A Pilot Injector CCV N G 0 25mm 2x CCV 5006N 6 B Pilot Injector CCV L P 0 20mm CCV 5006P 7 Electrode Ceramic CC...

Страница 27: ...costs must be borne by the Purchaser Exceptions This warranty will not apply 1 to defects or malfunctioning resulting from failure to properly install operate or maintain the unit in accordance with...

Страница 28: ...CE TECHNICIAN OR APPLIANCES SERVICES AND PARTS COMPANY INC ASAP INFORMATION BELOW MANUFACTURED BY ORBIS MERTIG SAIC YERBAL 1200 1607 VILLA ADELINA PROVINCIA DE BUENOS AIRES ARGENTINA IMPORTED BY THE G...

Страница 29: ...ide of the unit above the gas valve See figure 13 With the cover still off mount blower into the wall directly under and centered on the unit using the two fastening screws provided See figure 12 for...

Страница 30: ...ESCRIPTION PART NUMBER OF PART NUMBER 1 A Blower kit Calorama Comfort View I BK 1 1 B Blower kit Calorama Comfort View II BK 2 1 C Blower kit Calorama Comfort View III BK 3 1 D Blower Fan All Units BK...

Отзывы: