2-52
INSTALLATION
ORBAN MODEL 8685
xx-xx-xx-xx
Memory Total: 16121856
Memory Available: 6598384
Available Space: 8504 Kbytes
Dialnorm value=00
485 loopback ok
Connecting to the 8685’s Ethernet Port or RS-232 Port Using
TCP/IP
You can connect a terminal emulation application that supports the TCP/IP protocol
to the 8685 via its RS-232 or Ethernet ports. This is mainly useful when interfacing
the 8685 to third-party automation systems that support TCP/IP. If such an automa-
tion system only supports ASCII serial commands, you must configure the 8685’s se-
rial port as described in
Connecting via the RS-232 Port Using a Terminal Program on
a PC
on page2-46.
•
If you wish to use the RS-232 port for this application or for connecting to 8685
PC Remote software running on a PC, the port must be configured as
D
IRECT
or
M
ODEM
, either of which will load the port’s PPP driver following a reboot.
If you will be using Ethernet, the RS-232 configuration does not matter.
A)
From the main menu,
LOCATE
to
S
YSTEM
S
ETUP
>
N
ETWORK
R
EMOTE
>
N
ETWORK
.
The current setting of the RS-232 Serial Port will appear. Set it to
D
IRECT
.
(M
ODEM
will also work.)
If you plan to connect the 8685 PC Remote Application to the 8685’s RS-
232 serial port, you must choose
D
IRECT
or
M
ODEM
as appropriate for the
kind of connection you are planning to make —
D
IRECT
for a null modem
cable connection to a PC’s RS-232 serial port and
M
ODEM
for a modem
connection. Either choice will cause the 8685’s PPP serial port driver to be
loaded the next time the 8685 is booted up.
B)
If you have changed the configuration of the RS-232 from
ASCII
, you must
power-cycle the 8685. It will reboot and load the new serial driver.
•
You can connect a terminal emulation application to the 8685’s Ethernet or RS-
232 Serial ports via TCP/IP, port 23 (which is the standard Telnet port and the
8685 factory default). When connected like this, you can:
•
recall Presets (which contain the settings that determine the “sound” of the
processing); see step 1 on page 2-47
•
recall Setups (which contain technical settings for input levels, output levels,
routing, etc.); see step 2 on page 2-48
However, you cannot perform other administrative functions. These require op-
erating the 8685 from its front panel (which is the most straightforward way), us-
ing 8685 PC Remote software, or connecting a terminal program to the RS-232
Содержание OPTIMOD 8685
Страница 1: ...Operating Manual OPTIMOD 8685 Surround Audio Processor Version 1 0 Software...
Страница 7: ...Operating Manual OPTIMOD 8685 Surround Audio Processor Version 1 0 Software...
Страница 28: ...X XLR connector wiring standard 2 8...
Страница 54: ......
Страница 120: ...2 66 INSTALLATION ORBAN MODEL 8685 NOTES...
Страница 144: ......
Страница 244: ......
Страница 293: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 37...
Страница 294: ...6 38 TECHNICAL DATA ORBAN MODEL 8685 Base Board Parts Locator Drawing for schematic 62165 000 06...
Страница 299: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 43 CPU MODULE Drawing 32200 000 02...
Страница 305: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 49 RS232 Board Parts Locator Drawing for schematic 62250 000 02...
Страница 310: ...6 54 TECHNICAL DATA ORBAN MODEL 8685 8585 Digital I O SRC Control Miscellaneous Parts Locator 32330 000 02 1...
Страница 317: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 61 DSP BOARD PARTS LOCATOR DIAGRAM FOR SCHEMATIC 62375 000 xx 1...
Страница 327: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 71 LCD CARRIER PARTS LOCATOR 32270 000...
Страница 329: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 73 ENCODER BOARD PARTS LOCATOR HEADPHONE BOARD PARTS LOCATOR...
Страница 332: ...6 76 TECHNICAL DATA ORBAN MODEL 8685 FRONT PANEL INTERFACE BOARD PARTS LOCATOR DRAWING...
Страница 335: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 79 HD SDI I O BOARD Parts Locator Drawing top 32360 000 sheet 1 of 2...
Страница 336: ...6 80 TECHNICAL DATA ORBAN MODEL 8685 HD SDI I O BOARD Parts Locator Drawing bottom 32360 000 sheet 2 of 2...
Страница 354: ...6 98 TECHNICAL DATA ORBAN MODEL 8685 HD SDI RS232 RS485 SDI BOARD PARTS LOCATOR DRAWING 32365 000 sheet 1 of 1...
Страница 357: ...OPTIMOD SURROUND PROCESSOR TECHNICAL DATA 6 101...