Reset Switch – Turn the Roller Button to reset the switch 1 to 8 or None to position up, mid or
down
Press and hold the Roller button to save an exit
or press the cancel key to exit without saving
Down and up Mode:
Timer State – Turn the Roller button to select “Stop” or “Run”. If “Run” is selected, the timer is
counted up
Reset - Press and hold the cancel key to reset the timer if needed, then press the Roller button
Set up – Turn the Roller button to set the time in min. and sec.
Enable Switch – Turn the Roller Button to enable the switch 1 to 8 or None to position up, mid
or down
Reset Switch – Turn the Roller Button to reset the switch 1 to 8 or None to position up, mid or
down
Press and hold the Roller button to save an exit
or press the cancel key to exit without saving
a. Use the wheel to change the status of the switch then press the wheel.
b. Use the wheel to change the reset switch then press the wheel.
c. Use the wheel to change the status of the switch then press the wheel.
d. Press and hold the wheel to save an exit, or press the cancel key to exit without saving.
14
6 CHANNEL TRANSMITTER
DIGITAL PROPORTIONAL RADIO
CONTROL SYSTEMPROGRAMABLE SYSTEM
Mode - Turn the Roller button to select a mode (Up, Down, Down then up)
Up Mode:
Timer State – Turn the Roller button to select “Stop” or “Run”. If “Run” is selected, the timer is
counted up
Reset - Press and hold the cancel key to reset the timer if needed, then press the Roller button
Enable Switch – Turn the Roller Button to enable the switch 1 to 8 or None to position up,
mid or down
Reset Switch – Turn the Roller Button to reset the switch 1 to 8 or None to position up, mid or
down
Press and hold the Roller button to save an exit
or press the cancel key to exit without saving
Down Mode:
Timer State – Turn the Roller button to select “Stop” or “Run”. If “Run” is selected, the timer is
counted up
Reset - Press and hold the cancel key to reset the timer if needed, then press the Roller button
Set up – Turn the Roller button to set the time in min. and sec.
Enable Switch – Turn the Roller Button to enable the switch 1 to 8 or None to position up, mid
or down
RX:
This setting is used to sound an alarm when the receiver battery voltage drops dangerously low
Batt:
This setting is used to sound an alarm when the voltage out of range
Temp:
Temperature information is came from an optional Temperature sensor. If it becomes higher or
lower than the settling, an alarm will alert you
Current information is came from a optional Current sensor. If it becomes higher or lower that the
settling. And alarm will alert you
RPM:
RPM information is came from an optional RPM sensor. Min value indicates that the alarm will
start when the RPM falls below the set value. Max value indicates that the alarm will start when
RPM rises above the set value