Install a Flash Riser Board
Related Information
■
“Install a Flash Riser Board” on page 101
Install a Flash Riser Board
The system motherboard provides two slots (labeled
M.2 R 0
and
M.2 R 1
) for flash riser
boards. When installing flash riser boards, install the first riser board into slot
M.2 R 0
and then
into
M.2 R 1
.
1.
Unpack the replacement flash riser board and place it on an antistatic mat.
If required, ensure that you have installed an M.2 flash SSD onto the riser board before
installing the riser board into the server. See
“Install an M.2 Flash SSD” on page 105
.
2.
Install the flash riser board.
a.
Ensure that the ejector tabs are in the open position.
b.
Align the notch in the replacement riser board with the connector key in the
connector socket.
The notch ensures that the riser board is oriented correctly.
c.
Push the riser board into the connector socket until the riser board is
securely seated in the socket.
Servicing the Internal M.2 Flash SSDs (CRU)
101
Содержание X7-2L
Страница 1: ...Oracle Server X7 2L Service Manual Part No E72474 02 October 2017 ...
Страница 2: ......
Страница 12: ...12 Oracle Server X7 2L Service Manual October 2017 ...
Страница 14: ...14 Oracle Server X7 2L Service Manual October 2017 ...
Страница 48: ...48 Oracle Server X7 2L Service Manual October 2017 ...
Страница 66: ...66 Oracle Server X7 2L Service Manual October 2017 ...
Страница 84: ...84 Oracle Server X7 2L Service Manual October 2017 ...
Страница 92: ...92 Oracle Server X7 2L Service Manual October 2017 ...
Страница 110: ...110 Oracle Server X7 2L Service Manual October 2017 ...
Страница 130: ...130 Oracle Server X7 2L Service Manual October 2017 ...
Страница 138: ...138 Oracle Server X7 2L Service Manual October 2017 ...
Страница 142: ...142 Oracle Server X7 2L Service Manual October 2017 ...
Страница 156: ...156 Oracle Server X7 2L Service Manual October 2017 ...
Страница 164: ...164 Oracle Server X7 2L Service Manual October 2017 ...
Страница 172: ...172 Oracle Server X7 2L Service Manual October 2017 ...
Страница 178: ...178 Oracle Server X7 2L Service Manual October 2017 ...
Страница 218: ...218 Oracle Server X7 2L Service Manual October 2017 ...
Страница 224: ...USB Ports Reconnect Power and Data Cables on page 216 224 Oracle Server X7 2L Service Manual October 2017 ...
Страница 254: ...254 Oracle Server X7 2L Service Manual October 2017 ...