To Verify That the Label of a RAID Volume Is Valid
#
format
Searching for disks...done
c5t5000C5000B304CAFd0: configured with capacity of 136.71GB
c5t5000C5000B305B4Fd0: configured with capacity of 136.71GB
c5t5000CCA0002CF034d0: configured with capacity of 136.71GB
c5t5000CCA000310014d0: configured with capacity of 136.71GB
AVAILABLE DISK SELECTIONS:
0. c5t5000C5000B304CAFd0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
/scsi_vhci/disk@g5000c5000b304caf
1. c5t5000C5000B305B4Fd0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
/scsi_vhci/disk@g5000c5000b305b4f
2. c5t5000CCA0002CF034d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
/scsi_vhci/disk@g5000cca0002cf034
3. c5t5000CCA000310014d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
/scsi_vhci/disk@g5000cca000310014
Specify disk (enter its number):
2.
When prompted, type the number of a disk drive that is attached to the newly
installed HBA card, and press Enter.
#
format
Searching for disks...done
c5t5000C5000B304CAFd0: configured with capacity of 136.71GB
c5t5000C5000B305B4Fd0: configured with capacity of 136.71GB
c5t5000CCA0002CF034d0: configured with capacity of 136.71GB
c5t5000CCA000310014d0: configured with capacity of 136.71GB
AVAILABLE DISK SELECTIONS:
0. c5t5000C5000B304CAFd0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
/scsi_vhci/disk@g5000c5000b304caf
1. c5t5000C5000B305B4Fd0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
/scsi_vhci/disk@g5000c5000b305b4f
2. c5t5000CCA0002CF034d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
/scsi_vhci/disk@g5000cca0002cf034
3. c5t5000CCA000310014d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848>
/scsi_vhci/disk@g5000cca000310014
AVAILABLE DISK SELECTIONS:
Specify disk (enter its number):
2
selecting c5t5000CCA0002CF034d0
[disk formatted]
The Format menu is displayed.
3.
If you see a
Disk not labeled. Label it now?
message, type
y
to label the selected
disk.
50
Sun Storage 6 Gb SAS PCIe HBA, Internal Installation Guide For HBA Models SGX-SAS6-INT-Z and SG-SAS6-INT-Z
• May 2017
Содержание SG-SAS6-INT-Z
Страница 2: ......