Functions
77
-
Additionally, a separate
port number
must be configured.
The selected number can be between 1 and
65535.
If several cameras with different port numbers are connected and a specific camera is to be communicated
with, the corresponding camera can be determined via
Listen on port number
.
The port range used should be between
49152 ... 65535
. When using other ports, it could be
that they are already reserved or assigned.
When using multiple Xi 80/410 cameras in a network, the data rate must be considered:
➢
Switch with 100 Mbps: approx. 17 devices (Xi 80), approx. 2 devices (Xi 410 with 25 Hz)
➢
Switch with 1000 Mbps: approx. 170 devices (Xi 80), approx. 26 devices (Xi 410 with
25 Hz)
In addition to the data rate also make sure the power performance of the PC is high enough.
Each device used requires its own instance.
Содержание Xi 400
Страница 1: ...Operator s Manual optris Xi 80 400 410 Spot finder IR camera...
Страница 27: ...Mechanical Installation 27 Figure 5 Xi 80 dimensions mm...
Страница 28: ...28 Figure 6 Xi 400 dimensions mm...
Страница 29: ...Mechanical Installation 29 Figure 7 Xi 410 dimensions mm...
Страница 30: ...30 Figure 8 Industrial stackable PIF Process Interface electronic box control box shutter dimensions mm...
Страница 34: ...34 Figure 11 Mounting bracket ACXIAPLAB dimensions mm weight 276 g...
Страница 36: ...36 Figure 12 Water cooling ACXIW and mounting kit ACXIxxxWAK1 dimensions mm weight 1710 g...
Страница 37: ...Mechanical Installation 37 Figure 13 Shutter for water cooling ACXISW dimensions mm weight 600 g...
Страница 39: ...Mechanical Installation 39 Figure 14 Shutter ACXIS with mounting bracket ACXIAPLAB dimensions mm weight 826 g...
Страница 40: ...40 Figure 15 Shutter ACXIS dimensions mm weight 550 g...
Страница 71: ...Functions 71 Figure 35 Possibilities of power supply for Xi 80 410 via Ethernet connection...
Страница 79: ...Functions 79 Figure 37 Configurations menu Device PIF Figure 38 Setup...
Страница 92: ...92 7 2 Software window Figure 45 Software window 1 2 3 2 5 6 7 9 4 10 11 12 1 8...
Страница 107: ...Appendix A Table of emissivity for metals 107 Appendix A Table of emissivity for metals...
Страница 108: ...108...
Страница 109: ...Appendix B Table of emissivity for non metals 109 Appendix B Table of emissivity for non metals...
Страница 118: ...118 Figure 58 Relay output at industrial PIF...
Страница 119: ...Appendix G Declaration of Conformity 119 Appendix G Declaration of Conformity...
Страница 120: ...optris Xi MA E2021 08 A...