Motorised laser power attenuator 

Congratulations  on  your  purchase  of  the  advanced 
motorised laser power attenuator from Optogama, UAB.  

*** 

September 2019 

Copyright UAB Optogama. All rights reserved. 

No  part  of  this  manual  may  be  reproduced,  transmitted  in 
any form without the permission of Optogama. 

Claims will not be accepted and warranty repair will not be 
carried  out  in  case  of  improper  use,  incorrect  service  and 
maintenance  not  according  to  product  instructions. 
Warranty claim shall not be accepted if there are any signs 
of: 

Non-authorised alteration 

Disassembling of the device 

Mechanical or any external damage 

If warranty term has expired 

Serial number of the product is missing 

Symbols

CAUTION! 

Sections  marked  with  this  symbol  indicate  dangerous 
situations  that  can  result  in  damage  to  the  device,  
components connected to it or operator. 

NOTE: 

Sections  marked  with  this  symbol  indicate  important 
information on laser power attenuator or about this manual. 

Due  to  constant  development  of  our  products  we  reserve 
the  right  to  make  changes  in  the  production  line  without 
further  notice.  Up-to-date  information  is  available  at  our 
website 

www.optogama.com

.  If  there  are  any  further 

questions, please contact us. 

Optogama is not liable for damage or injury resulting directly 
or indirectly from use of this product for anything other than 
its intended purpose.  

The  motorised  laser  power  attenuator  is  intended  for 
industrial  and  scientific  use  only.  If  there  are  any  other 
electrical devices connected to or used in conjunction with 
the laser power attenuator, all legal regulations and technical 
standards  that  are  applied  to  those  devices  must  be 
observed as well.  

For  any  technical  assistance  and  consultation  please 
contact your local dealer or directly 

[email protected]

.

3

Содержание LPA-A v2 Series

Страница 1: ...MANUAL v2 2 LPA A ADVANCED and INTEGRATED MOTORISED LASER POWER ATTENUATOR LPA A v2 series KEY for DISCOVERIES ...

Страница 2: ...ller 7 3 5 1 Interfaces pinout 7 3 6 Voltage levels 7 3 7 What s in the box 7 3 8 Available accessories 7 4 Software 8 4 1 Minimum Hardware requirements recommended 8 4 2 System requirements 8 4 3 Supported client operating systems 8 4 4 Installing the software 8 4 5 Using the software 10 4 5 1 Connection device selector 10 4 5 2 Settings calibration 10 4 5 3 Main window 11 4 6 Updating the firmwa...

Страница 3: ... result in damage to the device components connected to it or operator NOTE Sections marked with this symbol indicate important information on laser power attenuator or about this manual Due to constant development of our products we reserve the right to make changes in the production line without further notice Up to date information is available at our website www optogama com If there are any f...

Страница 4: ...ice is installed correctly and well adjusted and all cover stickers are removed Protective measures should be considered if necessary Electrical safety requirements must be complied while operating this device CAUTION High laser output power may damage or destroy optical elements CAUTION The device is meant to be used with a collimated beam Users take full responsibility when using the device with...

Страница 5: ...le α should be adjusted to improve device contrast 2 deg maximum Use HEX 1 5 key Clock wise to decrease angle Counter clock wise to increase angle Fig 2 Schematic explanation of optical design of laser power attenuator LPA A 2 2 Features and advantages Integrated controller Absolute position encoder no homing required High accuracy 0 005 deg less than 0 01 of laser power Resolution 0 002 deg 7 2 a...

Страница 6: ...tions 3 2 Mechanical specifications 3 3 Electronic specifications 3 4 Conditions Clear input aperture ø15 mm Clear output aperture ø15 mm Power attenuation range 0 1 to 98 LIDT coating 10 J cm2 10 ns 1064 nm Adjustment time 0 2 sec min to max Aboslute pos encoder Yes Resolution 175 542 µsteps in full rotation 0 002 deg 7 2 arcsec 0 035 mrad Accuracy 0 005 deg 18 arcsec 0 087 mrad less than 0 01 Mo...

Страница 7: ...f up to 15 V Because the voltage levels are higher than logic levels typically used by integrated circuits special intervening driver circuits are required to translate logic levels These also protect the device s internal circuitry from short circuits or transients that may appear on the RS 232 interface and provide sufficient current to comply with the slew rate requirements for data transmissio...

Страница 8: ... Vista SP2 Windows 7 SP1 Windows 8 Windows 8 1 NET included with OS Windows 10 NET 4 6 included with OS Windows Server 2008 SP2 R2 Windows Server 2012 NET included with OS 4 4 Installing the software 1 Check and download the latest LPA software from our website www optogama com www 4lasers com or contact us directly at sales optogama com 2 Run the downloaded software installation file Installation...

Страница 9: ...the device and controller via HD 15 cable 6 Connect the PC and controller via USB or RS232 cable 7 Plug in power supply to controller and AC adaptor to wall outlet 8 The device will be detected and configured 9 The device installation is complete 9 ...

Страница 10: ...st be deselected otherwise device will not be visible 4 5 2 Settings calibration 11 Using laser power attenuator for the first time the calibration is required The information window will appear 12 For LPA A calibration move your mouse to the left side of the window on a gear symbol from the sliding menu and select Settings Settings menu will appear 13 To succeed calibration please follow calibrat...

Страница 11: ... Emergency zero If active the attenuator will instantly go to minimum position 0 Desired power value in your desired units Enter required power value Press Enter To enable go to settings Connection Green device is connected Status Green blinking in motion Green target is reached Error Red indicates and error Drag cursor here to obtain error Reconnect Select this icon to reconnect the device if it ...

Страница 12: ...atible software had been delivered with device In order to update your device or rewrite device firmware USB cable must be used update through RS232 cable is not available 1 Click button Firmware Upgrader in the About tab of LPA software 2 In the opened window press Update button You will be asked if you really want to update device After a warning device motors will be shut down and update will s...

Страница 13: ...PA PWR _X XXX Command used to set a new power value in percentages LPA PWR _10 LPA PWR_10 000 LPA PWR _45 1 LPA PWR_45 100 LPA PWR _0 07 LPA PWR_0 070 LPA ANG LPA ANG_X XXX Command used to get the current angle value in degrees Read from absolute encoder 0 360 deg LPA ANG LPA ANG_22 143 LPA ANG _X XXX LPA ANG_X XXX Command used to set the angle value in degrees 0 360 LPA ANG _22 5 LPA ANG_22 500 L...

Страница 14: ...13 bit14 bit15 device calibration is done LPA STATUS LPA 1_0 LPA STATUS LPA 0_0 LPA STATUS LPA 1_2 LPA WL LPA WL_XXX Command used to get the design wavelength LPA WL LPA WL_355 LPA FW LPA _Firmware version Command used to get firmware version LPA FW LPA _1 0 0 1 LPA ID LPA _LPAAXXXXXX Command used to get serial number LPA ID LPA _LPAA190001 Other Echo Reset Motor ON OFF LPA ECHO LPA ECHO Command u...

Страница 15: ...4 3 Serial communication example in Python 15 ...

Страница 16: ...5 Technical drawings 16 ...

Страница 17: ...17 ...

Страница 18: ...OPTOGAMA UAB Mokslininku str 2A LT 08412 Vilnius Lithuania 37052194884 sales optogama com www optogama com ...

Отзывы: