54
LTDVE4CH-20 | INSTRUCTIONS MANUAL
Figure 15: the Setup light outputs LD1-LD4 web page
Each light output can be set independently. Each light output can have a different activation source,
a specific output current and independent maximum turn-on and minimum turn-off parameters.
Moreover, the protection against excessive turn-on time and protection against insufficient turn-off
time can be independently enabled or disabled for each light output.
Source
selects the activation source for the light output. It can be chosen between
Off
(default),
Generator GN1
,
Generator GN2
,
Generator GN3
,
Generator GN4
,
Generator
GN5
,
Generator GN6
,
Generator GN7
,
Generator GN8
,
Input TR1
,
Input TR2
,
Input TR3
,
Input TR4
and
Continuous
. When set to
Off
the light output
is disabled. When set to
Continuous
the light output is always active