12
LTDVE4CH-20 | INSTRUCTIONS MANUAL
7
SH3-
Output 3. Emitter terminal
20
SH3+
Output 3. Collector terminal
8
SH4-
Output 4. Emitter terminal
21
SH4+
Output 4. Collector terminal
Table 7: pinout of connector P4 for synchronization outputs
Figure 3: interface circuits for output synchronization
depicts the internal output
circuits. These outputs can be directly connected to voltages up to 60V.
Figure 3: interface circuits for output synchronization
Circuit specifications are summarized in
Table 8: specifications of output synchronization circuits
Please note the reported values are typical.
Parameter
Value
Unit
Note
Iout (typ)
10
mA
-
Iout (max)
15
mA
-
Uout (max)
30
V
-
Table 8: specifications of output synchronization circuits
8.4.3. Serial RS485 interface
The serial interface is available on the D+, D- and GND terminals of connector P4. These signals
are listed in
Table 9: pinout of serial interface in connector P4
. Be careful not to cross-connect the
serial interface signals.