EYDFA-33-PM-R Operation Manual  

 

R1.00 

 

 

Page 4 of 15 

 

 

Optilab, LLC

 

 

600 E. Camelback Road, Phoenix, AZ  85012 
Phone:  1-877-303-3888, Fax:  (602) 343-1489, Email:  [email protected] 

 

2. 

Product Specifications 

 

2.1  Product Overview 

 
This product is a high power Erbium / ytterbium co-doped fiber amplifier designed for 
applications  requiring  high  efficiency  optical  amplification  in  C-band  for  CW 
operations. It is a single stage booster amplifier delivering over 23 dB gain and up to 
+33  dBm  saturation  power  at  1550  nm.  It  is  a  self-contained,  turn-key  rackmount 
designed to supply high and stable gain across the specified range of the wavelength 
window. 
 

2.2  Features 

 

  Up to +33 dBm saturation power 

  Polarization maintained with high PER 

  Collimated Output (Optional) 

  Interlock safety feature 

2.3  Function Diagram 

 
In the following figure, a basic function diagram of the EYDFA-33-PM-R is given. This 
is a single stage amplifiers. It comes with input and output power monitoring, as well 
as isolations. 

 

 
 
 

 

 
 
 
 
 
 
 
 

+33 dBm
8/125, PM

AMP

Pump Lasers

Signal Input

Signal Output

+10 dBm
8/125, PM

99/1

Input 
Monitor

99/1

Output 
Monitor

Function Diagram 

Содержание EYDFA-33-PM-R

Страница 1: ...THER THAN THOSE SPECIFIED HEREIN MAY RESULT IN HAZARDOUS RADIATION EXPOSURE THE USER MUST READ THIS MANUAL BEFORE OPERATING THE PRODUCT OPERATIONS OTHER THAN THOSE DESCRIBED IN THIS MANUAL MAY RESULT...

Страница 2: ...00 08 08 2018 Manual introduced Optilab LLC 2018 All rights reserved Information in this document is subject to change without notice All pictures and diagrams are for illustration purposes only and t...

Страница 3: ...__________________6 3 2 Operation Instructions ______________________________________________________8 3 2 1Preparation Procedure ___________________________________________________8 3 2 2Start up Pro...

Страница 4: ...report There MUST be an input signal present before turning on the optical output Do NOT use this product in HIGH PEAK PULSE POWER 10W applications unless with the consent from the manufacturer Faili...

Страница 5: ...AL COMPONENTS CONNECTED TO THE OPTICAL OUTPUT MUST BE RATED FOR HIGH POWER USE It is highly recommended that these components be properly cooled to dissipate heat FOR CONTINUED PROTECTION AGAINST FIRE...

Страница 6: ...erformance Standards for Light Emitting Products 5 US Department of Labor OSHA Publication 8 1 7 Guidelines for Laser Safety and Hazard Assessment 6 Laser Safety Equipment Laurin Publishing 7 Laser sa...

Страница 7: ...and up to 33 dBm saturation power at 1550 nm It is a self contained turn key rackmount designed to supply high and stable gain across the specified range of the wavelength window 2 2 Features Up to 33...

Страница 8: ...put Power Stability 0 2 dB over 8 hours Optical Input Output Fiber Type 8 125 NA 0 12 PM Optical Input Output Connector FC APC fast axis aligned to slow axis Mechanical Specifications Operating Temper...

Страница 9: ...The Touch LCD display shows the parameters and optical settings of the EYDFA rackmount unit This is a touchscreen type display see section 3 2 3 for more information Output Power Enable Switch This sw...

Страница 10: ...remote control and monitoring through a PC workstation Ventilation Fans The ventilation fans ensure proper ventilation inside the unit The back panel and the two sides of this equipment should be plac...

Страница 11: ...off and make sure the key switch on the front panel is also off Interlock should be shorted using the provided accessory or connected to a compatible interlock device After plugging in the appropriat...

Страница 12: ...ight a parameter to change it will turn yellow When the parameter is highlighted use the INC button to cycle through the options For the pump current adjust each digit then press SAVE to engage the ne...

Страница 13: ...ry to short this port or connect it to a compatible interlock device If the interlock is open during normal operation the pump lasers will be turned off To re enable the pump laser output turn the out...

Страница 14: ...the command afterwards Syntax is CMD XX case sensitive READ This command displays system status including the current settings of each pump and maximum current setting Example of Response Optilab LLC...

Страница 15: ...input or optical input power is too small S Check whether optical input is present or check optical input power is correct according to the test report C Optical connectors are dirty S Disable optica...

Страница 16: ...moist wipe removes dust particles oil and contaminants that may damage or blot the end face of the connector during connection The dry wipe removes residual alcohol that may be ignited by optical emis...

Страница 17: ...posure or damage to the optical connector by optical emission 2 Moisten the swab by placing it on top of the alcohol dispenser and push down to saturate the swab 3 For receptacles adapters or other co...

Страница 18: ...effect all repairs under terms of the warranty providing the Product is returned to Optilab LLC as specified in the warranty statement The purchaser shall bear the freight charges incurred in returnin...

Отзывы: