1.2  Laser Safety References 

For more laser safety information, please refer to: 

1) Laser Institute of America(LIA) 
13501 Ingenuity Drive, S uite 128 
Orlando, Florida 32826 
Phone:407 380 1553, Fax: 407 380 5588 
Toll Free:1 800 34 LAS ER 
 
2) American National Standards Institute 
ANSI Z136.1, American National Standard for the Safe Us e of Lasers 
(Available through LIA) 
3) International Electro-technical Commission 
IEC 60825-1, Edition 1.2 
 
4) Center for Devices and Radiological Health 
21 CFR 1040.10 - Performance Standards for Light-Emitting Products 
 
5) US Department of Labor - OSHA 
Publication 8-1.7 - Guidelines for Laser Safety and Hazard Assessment 
 
6) Laser Safety Equipment 
Laurin Publishing 
 
7) Laser safety equipment and Buyer’s Guides

 

 

1.3  Accessories 

 
When  you  receive  this  product,  verify  the  accessories  specified  in  the 

product 

packing list

 are included. If there are any discrepancies, notify Optilab, LLC promptly. 

 
This product was carefully inspected before it left the manufacturer. It should be in 
proper working order upon receipt. You should, however, inspect the product for any 
damage that may have occurred in transit. If the shipping container or the packing 
material is damaged, keep it until the contents of the shipment have been checked 
to be free of mechanical and electrical damages. Notify Optilab, LLC promptly if any 
notable damage is found. 

 
 
 
 
 
 

Содержание EYDFA-33-PM-R

Страница 1: ...THER THAN THOSE SPECIFIED HEREIN MAY RESULT IN HAZARDOUS RADIATION EXPOSURE THE USER MUST READ THIS MANUAL BEFORE OPERATING THE PRODUCT OPERATIONS OTHER THAN THOSE DESCRIBED IN THIS MANUAL MAY RESULT...

Страница 2: ...00 08 08 2018 Manual introduced Optilab LLC 2018 All rights reserved Information in this document is subject to change without notice All pictures and diagrams are for illustration purposes only and t...

Страница 3: ...__________________6 3 2 Operation Instructions ______________________________________________________8 3 2 1Preparation Procedure ___________________________________________________8 3 2 2Start up Pro...

Страница 4: ...report There MUST be an input signal present before turning on the optical output Do NOT use this product in HIGH PEAK PULSE POWER 10W applications unless with the consent from the manufacturer Faili...

Страница 5: ...AL COMPONENTS CONNECTED TO THE OPTICAL OUTPUT MUST BE RATED FOR HIGH POWER USE It is highly recommended that these components be properly cooled to dissipate heat FOR CONTINUED PROTECTION AGAINST FIRE...

Страница 6: ...erformance Standards for Light Emitting Products 5 US Department of Labor OSHA Publication 8 1 7 Guidelines for Laser Safety and Hazard Assessment 6 Laser Safety Equipment Laurin Publishing 7 Laser sa...

Страница 7: ...and up to 33 dBm saturation power at 1550 nm It is a self contained turn key rackmount designed to supply high and stable gain across the specified range of the wavelength window 2 2 Features Up to 33...

Страница 8: ...put Power Stability 0 2 dB over 8 hours Optical Input Output Fiber Type 8 125 NA 0 12 PM Optical Input Output Connector FC APC fast axis aligned to slow axis Mechanical Specifications Operating Temper...

Страница 9: ...The Touch LCD display shows the parameters and optical settings of the EYDFA rackmount unit This is a touchscreen type display see section 3 2 3 for more information Output Power Enable Switch This sw...

Страница 10: ...remote control and monitoring through a PC workstation Ventilation Fans The ventilation fans ensure proper ventilation inside the unit The back panel and the two sides of this equipment should be plac...

Страница 11: ...off and make sure the key switch on the front panel is also off Interlock should be shorted using the provided accessory or connected to a compatible interlock device After plugging in the appropriat...

Страница 12: ...ight a parameter to change it will turn yellow When the parameter is highlighted use the INC button to cycle through the options For the pump current adjust each digit then press SAVE to engage the ne...

Страница 13: ...ry to short this port or connect it to a compatible interlock device If the interlock is open during normal operation the pump lasers will be turned off To re enable the pump laser output turn the out...

Страница 14: ...the command afterwards Syntax is CMD XX case sensitive READ This command displays system status including the current settings of each pump and maximum current setting Example of Response Optilab LLC...

Страница 15: ...input or optical input power is too small S Check whether optical input is present or check optical input power is correct according to the test report C Optical connectors are dirty S Disable optica...

Страница 16: ...moist wipe removes dust particles oil and contaminants that may damage or blot the end face of the connector during connection The dry wipe removes residual alcohol that may be ignited by optical emis...

Страница 17: ...posure or damage to the optical connector by optical emission 2 Moisten the swab by placing it on top of the alcohol dispenser and push down to saturate the swab 3 For receptacles adapters or other co...

Страница 18: ...effect all repairs under terms of the warranty providing the Product is returned to Optilab LLC as specified in the warranty statement The purchaser shall bear the freight charges incurred in returnin...

Отзывы: