39
Chapter 8. Trouble shooting
Problem
Symptom
Solution
No Power
Power LED Off
Check the connection of power cord to the OMM-1000
and AC power outlet and that make sure that power
switch is in the ON.
No Output
No Output present
Check the Input Output DVI cables are firmly connected to
each port of OMM-1000.
Check the Input and Output connection configuration you
want.
The display is not capable of handling graphic
resolution.
Check the compatibility of EDID in the EEPROM and
attached displays.
When a single Input is routed to multiple outputs,
lower resolution EDID should be selected.
EX> Input 1
Output 1 (UXGA) & Output 2(SXGA)
If EEPROM 1 store the display 1 EDID (UXGA), the
display 2 (SXGA) will not work due to resolution limit.
The source has stopped sending a graphic signal.
Check the Input source status by connecting it to available
monitor without the OMM-1000.