Opticon
OPR 3001
Specifications Manual
38
14. Reliability
MTBF (Mean Time Between Failures) of this product except for the laser diode and the mirror
motor scan unit is 30,000 hours.
Life cycle of the laser diode is 10,000 hours and that of the mirror motor scan unit is also
10,000 hours.
The estimate of MTBF and product life cycle is based on standard operation of the product
within the recommended temperature range and without extreme electronic or mechanical
shock.
15. Trigger and Read Options
The OPR 3001 has an optional auto trigger setting, which starts barcode reading automatically
by using sensor detection. When auto trigger is enabled, a laser beam is emitted and points to
the auto trigger area. The scanner starts barcode reading after detecting reflection from the
surface when the auto trigger is used.
Auto trigger distance: 40 mm from the edge of the scanner.
15.1. Trigger Modes
Disabled
: When this option is selected, the reader will stay on all the time.
Enabled
: After receiving a trigger signal, the barcode reader will turn on and the read
cycle starts. The reader will stay on for a time as set in 'Read time options'. The trigger
signal can be initiated in the following ways:
Auto trigger mode
: The read cycle automatically starts when a trigger signal is received
via sensor detection.
15.2. Auto Trigger Options
15.2.1.
Auto Trigger Sensor
Auto trigger mode is enabled by scanning a part of scan area with infrared. The
scanner will start scanning after the embedded CMOS sensor detects a change in
reflection from the object.
Conditions
Moving Speed:
100 ±10 mm/s
Angle:
Skew angle, excluding pitch angle and dead zone
Environmental Temperature and
Humidity:
Room temperature and humidity
Environmental luminance:
500 to 900 lx
Conditions for the auto trigger:
1. Barcode sheet: OPTOELECTRONICS Test Sheet (white)
Background: OPTOELECTRONICS Test Sheet (black)
2. Barcode sheet: OPTOELECTRONICS Test Sheet (black)
Background: OPTOELECTRONICS Test Sheet (white)