background image

Opticon 

OPR 3001 

Specifications Manual 

 
 
 
 

 

33 

12. Packaging Specifications 

12.1. Individual  Packaging  Specification 

Put the scanner in a protective foam bag and place it in a single packing box.  

The scanner shown is an RS-232C unit. Descriptions on an individual packaging box 
label differ, depending on the interface type. The “RO” mark may be indicated on the 
upper side of the individual packaging box label. 

 

Figure 23: Individual packaging  

Содержание OPR 3001

Страница 1: ...Handheld Laser Scanner OPR 3001 The OPR 3001 is a rugged handheld laser barcode scanner with protection against dust and splashing water to ensure reliable operation in harsh environments Specifications Manual ...

Страница 2: ...ts that are defective in materials or workmanship with proper use during the warranty period Opticon is not liable for damages caused by modifications made by a customer In such cases standard repair charges will apply If a product is returned under warranty and no defect is found standard repair charges will apply Opticon assumes no liability for any direct indirect consequential or incidental da...

Страница 3: ...1 Laser Scan Specifications 10 6 1 1 Tilt of Laser Scan Line 10 6 1 2 Curvature of Scan 11 7 Technical Specifications 11 7 1 Print Contrast Signal PCS 12 7 2 Minimum Resolution 12 7 3 Scan Area and Resolution 12 7 3 1 Depth of Field 12 7 4 Pitch Skew and Tilt 14 7 4 1 Pitch Angle 14 7 4 2 Skew Angle and Dead Zone 15 7 4 3 Tilt Angle 16 7 5 Curvature 17 8 Interface Specifications 17 8 1 RS 232C Int...

Страница 4: ...et Default Interface 28 10 2 Default Settings 1 Readable Codes 29 10 3 Default Settings 2 Read Options Trigger Buzzer 31 11 Serial Number 32 12 Packaging Specifications 33 12 1 Individual Packaging Specification 33 12 2 Collective Packaging Specification 34 13 Durability 35 13 1 Electrical Noise 35 13 2 Static Electricity 35 13 3 Shock 36 13 3 1 Drop Test without packaging 36 13 3 2 Drop Test with...

Страница 5: ...igure 1 Ambient light immunity 8 Figure 2 Laser scanning tilt and curvature 11 Figure 3 Scan area and resolution in mm 12 Figure 4 Pitch angle 14 Figure 5 Skew angle and dead zone 15 Figure 6 Tilt angle 16 Figure 7 Curvature 17 Figure 8 Interface circuit 18 Figure 9 Character format same for both sending and receiving 19 Figure 10 Communication format 19 Figure 11 No handshaking 19 Figure 12 Busy ...

Страница 6: ...Wedge cable 26 Figure 22 Serial number diagram 32 Figure 23 Individual packaging 33 Figure 24 Collective packing 34 Figure 25 Product drop test 36 Figure 26 Cable bend strength 37 Figure 27 Auto trigger detection area 39 Figure 28 Mechanical drawing 42 ...

Страница 7: ...withstands repeated drops of up to two meters onto concrete Short wavelength red laser beams enhance the visibility of scanning lines for easier aiming under adverse lighting conditions The OPR 3001 is available in USB RS 232C and Wedge interfaces Supported symbologies Linear 1D Postal 2D JAN UPC EAN incl add on Chinese Post Composite codes Codabar NW 7 Korean Postal Authority Code MicroPDF417 Cod...

Страница 8: ...erature and Humidity Temperature 10 to 60 C Humidity 5 to 90 RH 4 2 Storage Temperature and Humidity Temperature 30 to 70 C Humidity 5 to 90 RH 4 3 Ambient Light Immunity Decoding performance is guaranteed when the range of illumination on a barcode surface is between zero and the following values Incandescent light to 4 000 lx Fluorescent light to 4 000 lx Sunlight to 80 000 lx Figure 1 Ambient l...

Страница 9: ...es are defined 5 Electrical Specifications 5 1 Electrical Characteristics Parameter Symbol Min Typ Max Unit Remarks 5 4 6 0 6 6 V RS 232C Power supply voltage 4 5 5 0 5 5 V USB and Wedge 96 130 mA RS 232C when emitting Operating current IOP 90 125 mA USB and Wedge when emitting laser 400 600 mA RS 232C Rush current IPEEK 300 500 mA USB and Wedge 35 60 mA RS 232C Stand by current IPRE 30 55 mA USB ...

Страница 10: ...ction area 40 mm Notes Refer to chapter 15 Trigger and Read Options to read about the scan modes Refer to chapter 7 Technical Specifications to read about scanning performance 6 1 1 Tilt of Laser Scan Line Laser scanning tilt is the vertical difference between both ends of a laser scan line Measure it in the middle of the laser scan line Maximum tilt between both ends of laser scan line Less than ...

Страница 11: ... and curvature 7 Technical Specifications The conditions for technical specifications are as follows unless otherwise specified in each section Conditions Ambient temperature and humidity Room temperature 5 to 35º C Room humidity 45 to 85 RH Ambient light 500 to 900 lx Angles Omni scanning mode Pitch α 0 Skew β 0 10 Tilt γ 0 Mobile mode Pitch α 0 Skew β 0 Tilt γ 0 Background Barcode black Space wh...

Страница 12: ...r Reflectance of white bar Scanning performance may decline if dirt or scratches mar the optical window Keep the optical window clean 7 2 Minimum Resolution 0 127 mm 7 3 Scan Area and Resolution 7 3 1 Depth of Field The depth of field is measured from the edge of the scanner The scanning range is within the circular arc centered on the scan origin Figure 3 Scan area and resolution in mm ...

Страница 13: ...9 Code 39 0 25 mm 10 200 0 9 Code 39 0 15 mm 10 90 0 9 Code 39 0 127 mm 20 60 0 9 Conditions Barcode Sample OPTOELECTRONICS Test Sample N W Ratio 1 2 5 Angle α 0 β 15 γ 0 Curvature R Resolution Symbology PCS Quiet Zone Digit 1 0 mm Code 39 0 9 25 mm 1 0 5 mm Code 39 0 9 18 mm 3 0 25 mm Code 39 0 9 10 mm 8 0 15 mm Code 39 0 9 7 mm 10 ...

Страница 14: ...Opticon OPR 3001 Specifications Manual 14 7 4 Pitch Skew and Tilt 7 4 1 Pitch Angle α 35 α 3 5 α 3 5 Figure 4 Pitch angle ...

Страница 15: ...001 Specifications Manual 15 7 4 2 Skew Angle and Dead Zone Skew angle β 50 Excluding dead zone Dead zone β 8 There are some areas in which decoding fails due to specular reflection Figure 5 Skew angle and dead zone ...

Страница 16: ...dge of the scanner Label Pitch Angle Skew Angle Dead Zone PCS 0 9 Resolution 0 25 mm Symbology 9 digit Code 39 Quiet Zone 10 mm N W Ratio 1 2 5 Tilt Angle PCS 0 9 Resolution 0 26 mm Symbology 13 digit JAN Quiet Zone 10 mm Angle Pitch Angle Skew Angle β 15 Tilt Angle γ 0 Tilt Angle Pitch Angle α 0 Skew Angle β 15 Skew Angle Dead Zone Pitch Angle α 0 Tilt Angle γ 0 Curvature R ...

Страница 17: ...on 0 26 mm Quiet Zone 10 mm Distance 60 mm from the edge of the scanner Angle Skew Angle β 15 8 Interface Specifications 8 1 RS 232C Interface Specification 8 1 1 Settings and Communication Reading the menu barcodes in section 10 1 can set the RS 232C interface default Parameter U2 setting Baud rate 9600 bps Start stop bits 1 bit Data bits 8 bits Parity bits No parity Handshaking No handshake Flow...

Страница 18: ...ions Manual 18 8 1 2 Signal Level Signal Name I O RS 232C Level V Mark OFF Space ON TxD OUT 5 to 15 5 to 15 RxD IN 3 to 15 3 to 15 RTS OUT 5 to 15 5 to 15 CTS IN 3 to 15 3 to 15 8 1 3 Interface Circuit Figure 8 Interface circuit ...

Страница 19: ...n Format Figure 10 Communication format 8 1 6 Handshaking Select handshaking options using the menu or command listed below Handshaking Menu Command No handshake P0 BUSY READY P1 MODEM P2 ACK NAK P3 ACK NAK NO RESPONSE P4 a No Handshaking The scanner attempts the communication regardless of the state of the host computer Figure 11 No handshaking ...

Страница 20: ...n parts of the process such as receiving data buzzer command execution transmitting data and menu processing The scanner checks the CTS line before transmitting data When it is ON the scanner transmits data When it is OFF the scanner waits for it to turn ON within a set time The scanner will abort transmission with an error indication buzzer when the CTS line is not ON within a specified period Th...

Страница 21: ...scanner turns CTS line ON before transmitting data Other processes are the same as BUSY READY Figure 15 Modem transmit data d ACK NAK After data has been transmitted the scanner expects to receive one of the following responses from the host ACK response Action The scanner completes transmission with the good read buzzer and returns to the initial state NAK response Action The scanner sends the da...

Страница 22: ...on OPR 3001 Specifications Manual 22 ACK NAK timeout can be set as follows using the menu or commands ACK NAK timeout Menu Command Indefinitely default XI4 100 ms XI5 500 ms XI6 1000 ms XI7 Figure 16 ACK NAK ...

Страница 23: ... NAK NO RESPONSE When no response from the host is received within the setting time the scanner assumes an ACK response and returns to the initial state without the error buzzer The other actions are the same as ACK NAK Figure 17 ACK NAK No response ...

Страница 24: ...8 2 2 Interface Circuit Figure 18 USB interface circuit Do not operate the keyboard while the scanner is transmitting the data to the host it may cause data transactions to fail 8 3 DOS V Wedge Interface Specification Reading the menu barcodes in section 10 1 can set the DOS V Wedge interface default Do not operate the keyboard while the scanner is transmitting the data to the host it may cause da...

Страница 25: ...ed wires 1 conductive wire Weight Approximately 80 g 9 1 1 Pin Assignment Pin No Signal Name Notes 1 NC Open not assigned 2 TXD 3 RXD 4 Pin no 6 and jumper 5 GND 6 Pin no 4 and jumper 7 CTS 8 RTS 9 NC Open not assigned Connector A connector with a plug for external power supply D sub 9 pin female Power Supply φ4 0 inside diameter φ1 7 Exterior electrode of the plug is GND and interior electrode is...

Страница 26: ...ification Figure 20 USB cable Type Straight Diameter Φ4 8 0 5 mm Length 1500 50 0 mm Cores 4 insulated wires 1 conductive wire Weight Approximately 60 g 9 2 1 Pin Assignment Pin Signal 1 VCC 2 DATA 3 DATA 4 GND 9 3 Wedge Cable Standard specification Figure 21 Wedge cable ...

Страница 27: ...OS V Keyboard Side Pin No Signal Name Pin No Signal Name 1 CPU_DATA 1 KEY_DATA 2 2 3 GND 3 GND 4 VCC 4 VCC 5 CPU_CLK 5 KEY_CLK 6 6 9 4 Connector Specification Scanner Side CN801 13 pin Signal Name Pin Number RS 232C USB Wedge 1 NC VCC VCC 2 R D NC NC 3 T D NC NC 4 NC NC CPU_CLK 5 NC NC CPU_DATA 6 GND GND GND 7 NC USB NC 8 NC USB NC 9 NC NC KB_DATA 10 NC NC KB_CLK 11 CTS NC NC 12 RTS NC NC 13 VCC N...

Страница 28: ...RS 232C _U2_ U2 Single tone buzzer 3 kHz _W1_ W1 Buzzer duration 50 ms _W7_ W7 Read mode options Single read _S0_ S0 END _ZZ_ ZZ If you are using software version TS01Y04 or later it is not necessary to configure the foregoing settings USB HID Default Functions Menu labels Menu codes SET _ZZ_ ZZ USB default _SU_ SU END _ZZ_ ZZ USB VCP Functions Menu labels Menu codes SET _ZZ_ ZZ USB VCP _C0_ C01 E...

Страница 29: ... codes SET _ZZ_ ZZ AT Wedge default _UB_ UB Keyboard layout without keyboard _KL_ KL END _ZZ_ ZZ 10 2 Default Settings 1 Readable Codes Symbology Read Transmit Code Length Transmit CD Calculate CD Set Prefix Set Suffix Other UPC A X CR UPC A Add on X X CR UPC E X CR UPC E Add on X X CR EAN 13 X CR EAN 13 Add on X X CR EAN 8 X CR EAN 8 Add on X X CR Chinese Post 2of5 X X X CR Codabar NW 7 X X CR No...

Страница 30: ...F417 X X CR PDF417 X X CR MSI Plessey X CD1 CD1 CR S Code X X CR Telepen X X CR Trioptic X CR Not transmit ST SP UK Plessey X CR Notes In the Reading column means Enable reading and X means Disable reading In the Transmit code length column means Transmit code length and X means Do not transmit code length In the Transmit CD column means Transmit check digit and X means Do not transmit check digit...

Страница 31: ... 500 ms Add on wait mode 500 ms Multiple label read Disable Multiple column read Disable Redundancy Read 1 times redundancy 0 Trigger switch Enable Trigger repeat Disable Auto trigger Disable Read time 2 seconds when trigger enabled Margin check Normal Buzzer duration 50 ms Buzzer tone Single tone 3 kHz Buzzer loudness Maximum Buzzer timing Before transmission Startup buzzer Enable Good read LED I...

Страница 32: ...Opticon OPR 3001 Specifications Manual 32 11 Serial Number The serial number as shown below is affixed to the scanner Figure 22 Serial number diagram ...

Страница 33: ...the scanner in a protective foam bag and place it in a single packing box The scanner shown is an RS 232C unit Descriptions on an individual packaging box label differ depending on the interface type The RO mark may be indicated on the upper side of the individual packaging box label Figure 23 Individual packaging ...

Страница 34: ...ndicated on the upper side of the individual packaging box label Figure 24 Collective packing Note The RO mark labeled on the package tray or package box guarantees that the applicable product has passed our test of RoHS restrictions compliance the restriction of the use of certain hazardous substances in electrical and electronic equipment 2002 95 EC However this document does not have any legal ...

Страница 35: ...on 0 25 mm Symbology 9 digit Code 39 Quiet Zone 10 mm N W Ratio 1 2 5 Distance 100 mm Angle α 0 β 15 γ 0 Curvature R Power Supply Voltage 6 0 V RS 232C 5 0 V USB and Wedge 13 2 Static Electricity Air discharge 8 kV max No malfunction 15 kV max No destruction Contact discharge 6 kV Contact discharge at the hook and the screw Measurement environment Use electrostatic testing device compliant with IE...

Страница 36: ...crete floor ten times from random angles on its top bottom front back left right top left top right bottom left bottom right 13 3 3 Vibration without packaging Swept with 10 Hz to 100 Hz acceleration 19 6 m s2 2 0G Added a vibration to each X Y and X direction for 30 minutes 1 cycle 60 minutes under non operational conditions Observed no abnormality in either appearance or performance 13 3 4 Vibra...

Страница 37: ...ul effect 13 5 Cable Strength Affixed the scanner to an immovable object and pulled it using a force of 49N 5 0 kgf for 1 minute Observed no abnormality in either structure or performance 13 6 Cable Bending Test As shown below added a load of 4 9N 500 g to a cable then bent it at an angle of 90 degrees to both right and left Count 1 time by bending to either side repeated this 3 million times on R...

Страница 38: ... 1 Trigger Modes Disabled When this option is selected the reader will stay on all the time Enabled After receiving a trigger signal the barcode reader will turn on and the read cycle starts The reader will stay on for a time as set in Read time options The trigger signal can be initiated in the following ways Auto trigger mode The read cycle automatically starts when a trigger signal is received ...

Страница 39: ...Enable Disable Settings Use the following settings to enable or disable the auto trigger Auto trigger is disabled by default To enable auto trigger scan ZZ I and ZZ in that order To disable auto trigger scan ZZ F and ZZ in that order Functions Menu labels Menu codes SET _ZZ_ ZZ Disable auto trigger _ F_ F Enable auto trigger _ I_ I END _ZZ_ ZZ ...

Страница 40: ...be used in a domestic environment based on the Technical Requirement of the Voluntary Control Council for Interference from Information Technology Equipment VCCI If this is used near a radio or television receiver in a domestic environment it may cause radio interference Please install and use the equipment according to the instruction manual FCC Part 15 Subpart B Class B This device complies with...

Страница 41: ...throw the scanner into the fire Do not forcibly bend the cables at low temperatures 18 3 Foreign Materials Do not immerse the scanner in liquids Do not subject the scanner to chemicals 18 4 Other Do not plug unplug the connectors before disconnecting the power Do not disassemble this product Do not place the product near a radio or a TV receiver as the scanner may cause reception problems The scan...

Страница 42: ...Opticon OPR 3001 Specifications Manual 42 19 Mechanical Drawing Dimensions 3 W 68 X D 150 X H 155 mm except protruding portion Figure 28 Mechanical drawing ...

Отзывы: