6. Optical
Specifications
6.1. Laser Scan Specifications
Parameter Specification
Unit
Light-emitting element
Red laser diode
—
Emission wavelength
650 ±10 (25° C)
nm
Light output
1.0 or less
mW
Scanning method
Bi-directional scanning
—
Scanning speed
100 ±20
scans/s
Scan angle: 54 ±5
°
Scan angle
Read angle: 44 (Min)
°
Auto-trigger IR detection area
40
mm
Notes:
Refer to chapter 15, “Trigger and Read Options,” to read about the scan modes.
Refer to chapter 7, “Technical Specifications,” to read about scanning performance.
6.1.1.
Tilt of Laser Scan Line
Laser scanning tilt is the vertical difference between both ends of a laser scan
line. Measure it in the middle of the laser scan line.
Maximum tilt between both ends of laser scan line: Less than 1.2° upward tilt from
the scan origin.
Maximum of 3.1 mm when measured at a point 150 mm away from the scan
origin. (The skew angle of this measurement was zero degrees.)