M-10
Specifications Manual
17
9.6.
Pitch, Skew, and Tilt
Pitch
:
α
= ± 50°
Skew
:
β
= ± 50°
Tilt
:
γ
= 360°
<Conditions>
Barcode
: 0.33 mm UPC/EAN specified in Section 9.1
Distance
: 65 mm from the front edge of the Scanner
Curvature
: R =
∞
For the pitch angle and tilt angle measurement, set the skew angle
β
= +15°
Figure 12: Pitch, Skew, and Tilt
9.7.
Curvature
0.33 mm UPC/EAN
: R
≧
20 mm
<Conditions>
Barcode
: 0.33 mm UPC /EAN specified in Section 9.1
Distance
: 45 mm from the front edge of the scanner
Angle
:
α
= 0°,
β
=
+
15°,
γ
= 0°
Figure 13: Curvature
* The reading characteristics may deteriorate due to the specular reflection of LED illumination when the
reflectivity is high.