M-10
Specifications Manual
22
10.9. Drop Impact Strength (without packing)
Drop height : 1.5m
There shall be no sign of malfunction after the following drop test.
Drop test:
Drop the scanner three times (15 times in total), at each 5 face, from a height of 1.5m
onto a concrete floor as shown below.
Concrete floor
Figure 19: Drop Test
10.10. Drop Impact Strength (in individual packing)
There shall be no sign of malfunction after the following drop test.
Drop test:
Drop an individually packaged scanner 10 times in total, at any of 1 corner, 3 edges, and
6 faces, from a height of 1m onto a concrete floor.
10.11. Electrical Specifications
Withstand Voltage
: AC 1500 V / 60 seconds, 10 mA or less
Insulation Resistance
: DC 500 V, 2 M
Ω
or higher
Current Leakage
: 250
μ
A or less / AC 250 V 60 Hz
Power Line Noise Immunity
: ±1 kV or lower
Electrostatic Discharge Immunity
: No destruction found (± 15 kV, air or direct discharge)
: No malfunction found (± 10 kV, air or direct discharge)
: ±6 kV (contact, direct or indirect discharge)
* Testing method is compliant with IEC-61000-4-2. (150 pF, 330
Ω
)