10.4. Dust & Water Proof Grade
IEC/EN 60529
Protection Level : IP52
10.5. Cable Strength
There shall be no sign of malfunction after the following cable strength test.
Cable Strength Test:
Affix the scanner to an immovable object and pull it using a force of 24.5 N
(2.5 kgf static loading) for 1 second. Repeat this 20 times continuously.
10.6. Cable Bending Strength
There shall be no sign of malfunction after the following cable bending test.
Cable Bending Test:
Add a load of 4.9 N (500 gf) to a cable and bend it at an angle of 60° to both
right and left. Repeat this 100000 times continuously.
Figure 18: Cable Bending
10.7. Vibration Strength (without Packing)
There shall be no sign of malfunction after the following vibration test.
Vibration test:
Increase the frequency of the vibration from 10 ~ 100 Hz at an accelerated velocity
of 19.6 m/s
2
(2.0 G) for 30 minutes (60 minutes per cycle) in the non-operating state. Repeat this in
each X, Y and Z direction.
10.8. Vibration Strength (in individual packing)
There shall be no sign of malfunction after the following vibration test.
Vibration test:
Increase the frequency of the vibration from 10 ~ 100 Hz at an accelerated velocity
of 19.6 m/s
2
(2.0 G) for 30 minutes (60 minutes per cycle) in individually packaged state. Repeat this
in each X, Y and Z direction.