M-10
Specifications Manual
13
9. Technical Specifications
Code reading is performed by positioning the aiming light over the center of a code. The conditions for
technical specifications are as follows, unless otherwise specified in each section.
<Conditions>
Temperature and humidity
: Room temperature and room humidity
Ambient light
: 100 ~200 lx (on the surface of a barcode)
Pitch angle
:
α
= 0°
Skew angle
:
β
= 15°
Tilt angle
:
γ
= 0°
Curvature
: R =
∞
Power supply voltage
: 3.3 and 5.0 V
PCS (1D and 2D)
: 0.9 or higher
Reading test
: 1 read in 2 seconds or less. Accept the performance
with 90% or more success rate for 10 readings.
Barcode test sample (1D and 2D)
: Specified below
<Barcode test sample>
1D codes
OPTOELECTRONICS test samples
GS1 Databar, stacked codes, 2D codes
Labels printed by a dedicated printer for barcode