VLAN
VLAN Mode Setting, 802.1Q VLAN Setting, 802.1Q Port Setting, Port Based VLAN
802.1Q VLAN SETTING
VLAN Database:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use
vlan database
command to enter the VLAN configuration mode.
3.
Command Syntax:
vlan database
4.
Example:
The following example changes to VLAN configuration mode from Configure mode:
switch_a(config)#vlan database
switch_a(config-vlan)#
Add VLAN/Delete VLAN:
1.
Command Mode: VLAN Configure mode
Logon to Configure Mode (Configure Terminal Mode).
Logon to VLAN Configure Mode.
The
switch_a(config-vlan)#
prompt will show on the screen.
switch_a(config)#vlan database
switch_a(config-vlan)#
2.
Usage:
This command enables or disables the state of a particular VLAN on a bridge basis. Specifying the
disable state causes all forwarding over the specified VLAN ID on the specified bridge to cease.
Specifying the enable state allows forwarding of frames on the specified VLAN-aware bridge.
3.
Command Syntax:
vlan VLANID bridge GROUP name VLAN_NAME state enable/disable
no vlan VLANID bridge GROUP
VLANID The VID of the VLAN that will be enabled or disabled on the bridge <2-4094>.
GROUP <1-1> The ID of the bridge-group on which the VLAN will be affected.
VLAN_NAME The ASCII name of the VLAN. Maximum length: 16 characters.
enable Sets VLAN into an enable state.
disable Sets VLAN into a disable state.
4.
Example:
The following example enables the vlan VLANID (
2
) and name VLAN_NAME (
vlan2
) of bridge
GROUP (
1
):
switch_a(config-vlan)#vlan 2 bridge 1 name vlan2 state enable
switch_a(config-vlan)#
Содержание OSD2700SFP SERIES
Страница 1: ...OPERATOR MANUAL OSD2700SFP SERIES MANAGED 24 PORT 100BASE SFP AND 4 COMBO PORT GIGABIT ETHERNET SWITCH...
Страница 2: ......
Страница 43: ...OPTICAL SYSTEMS DESIGN DOC ID 10112704 OSD2700SFP OPERATOR MANUAL PAGE 43...
Страница 45: ...OPTICAL SYSTEMS DESIGN DOC ID 10112704 OSD2700SFP OPERATOR MANUAL PAGE 45...
Страница 54: ...OPTICAL SYSTEMS DESIGN DOC ID 10112704 OSD2700SFP OPERATOR MANUAL PAGE 54...
Страница 55: ...OPTICAL SYSTEMS DESIGN DOC ID 10112704 OSD2700SFP OPERATOR MANUAL PAGE 55...
Страница 57: ...OPTICAL SYSTEMS DESIGN DOC ID 10112704 OSD2700SFP OPERATOR MANUAL PAGE 57...
Страница 58: ...OPTICAL SYSTEMS DESIGN DOC ID 10112704 OSD2700SFP OPERATOR MANUAL PAGE 58...
Страница 61: ...OPTICAL SYSTEMS DESIGN DOC ID 10112704 OSD2700SFP OPERATOR MANUAL PAGE 61...
Страница 64: ...OPTICAL SYSTEMS DESIGN DOC ID 10112704 OSD2700SFP OPERATOR MANUAL PAGE 64...
Страница 67: ...OPTICAL SYSTEMS DESIGN DOC ID 10112704 OSD2700SFP OPERATOR MANUAL PAGE 67...
Страница 71: ...OPTICAL SYSTEMS DESIGN DOC ID 10112704 OSD2700SFP OPERATOR MANUAL PAGE 71...
Страница 81: ...OPTICAL SYSTEMS DESIGN DOC ID 10112704 OSD2700SFP OPERATOR MANUAL PAGE 81 6 12 SNMP...
Страница 94: ...OPTICAL SYSTEMS DESIGN DOC ID 10112704 OSD2700SFP OPERATOR MANUAL PAGE 94 6 15 OTHER PTOTOCOLS...
Страница 96: ...OPTICAL SYSTEMS DESIGN DOC ID 10112704 OSD2700SFP OPERATOR MANUAL PAGE 96...
Страница 101: ...OPTICAL SYSTEMS DESIGN DOC ID 10112704 OSD2700SFP OPERATOR MANUAL PAGE 101...
Страница 103: ...OPTICAL SYSTEMS DESIGN DOC ID 10112704 OSD2700SFP OPERATOR MANUAL PAGE 103...
Страница 221: ...OPTICAL SYSTEMS DESIGN DOC ID 10112704 OSD2700SFP OPERATOR MANUAL PAGE 221...
Страница 222: ...OPTICAL SYSTEMS DESIGN DOC ID 10112704 OSD2700SFP OPERATOR MANUAL PAGE 222...