OPTICAL SYSTEMS DESIGN
DOC ID: 10120001
OSD2524 OPERATOR MANUAL
PAGE 243
REFLECTOR PORT
The
reflector port
is a method to redirect the traffic to Remote Mirroring VLAN. Any device
connected to a port set as a reflector port loses connectivity until the Remote Mirroring is
disabled.
In the stacking mode, you need to select switch ID to select the correct device.
If you shut down a port, it cannot be a candidate for
reflector port
.
If you shut down the port which is a
reflector port
, the remote mirror function cannot work.
Note1: The reflector port needs to select only on Source switch type.
Note2: The reflector port needs to disable MAC Table learning and STP.
Note3: The reflector port only supports on pure copper ports.
SOURCE VLAN(S) CONFIGURATION
The switch can supports VLAN-based Mirroring. If you want to monitor some VLANs on the
switch, you can set the selected VLANs on this field.
Note1: The Mirroring session shall have either ports or VLANs as sources, but not both.
REMOTE MIRRORING PORT CONFIGURATION
The following table is used for port role selecting.
Port
The logical port for the settings contained in the same row.
Source
Select mirror mode.
Disabled
Neither frames transmitted nor frames received are mirrored.
Both
Frames received and frames transmitted are mirrored on the
Intermediate/Destination port
.
Rx only
Frames received on this port are mirrored on the
Intermediate/Destination port
. Frames
transmitted are not mirrored.
Tx only
Frames transmitted on this port are mirrored on the
Intermediate/Destination port
. Frames
received are not mirrored.
Intermediate
Select intermediate port.
This checkbox is designed for Remote Mirroring.
The
intermediate port
is a switched port to connect to other switch.
Note: The intermediate port needs to disable MAC Table learning.
Destination
Select destination port.
This checkbox is designed for mirror or Remote Mirroring.
The
destination port
is a switched port that you receive a copy of traffic from the source port.
Note1: On mirror mode, the device only supports one destination port.
Note2: The destination port needs to disable MAC Table learning.
Содержание OSD2524
Страница 1: ...User Manual OSD2524 MANAGED 20 x 10 100 1000BASE T RJ45 4 x COMBO RJ45 SFP 2 x 1G SFP ETHERNET SWITCH...
Страница 2: ......
Страница 14: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 14...
Страница 26: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 26...
Страница 234: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 234...
Страница 252: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 252 SFLOW CONFIGURATION Configuration sFlow...
Страница 310: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 310 ACL Status Monitor Security Network ACL Status...
Страница 339: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 339...
Страница 376: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 376 MAC TABLE Monitor MAC Table...
Страница 401: ...OPTICAL SYSTEMS DESIGN DOC ID 10120001 OSD2524 OPERATOR MANUAL PAGE 401...