52
Set Items List
The following table shows the functions, the setting range, and the initial
values of the set items whose settings are changeable.
Function name
LCD display
Setting range
(Initial value)
Explanation
Sensitivity of lack
for identit*
1
CMP LACK
0 – 15
(0)
0
: Average identity of the pixels not being
masked will be the identity.
1 – 15
: Set to one of these values for the
inspection of smear or lack. As the value
increases, the sensitivity to the number of
pixels of different color will be higher.
Threshold value
of identity*
1
CMPLEVEL
0 – 100
(70)
Sets the level of the identity to turn ON the
output. As the set value increases, higher
identity is required. Since negative value is also
processed internally, output may not turn ON
even when “
0
” is displayed for the identity if “0”
is set as the set value.
Color sensitivity
for identity*
1
CMPSENSE
0 – 15
(10)
Sets the level to permit the difference in color
against the registered pattern.“
0
” brings the
highest sensitivity and slight difference in color
can be distinguished.
Range of detection
color for position
correction*
1
COLOR% P
0 – 25
(1)
Sets the range of the color for the position
correction (margin against the color selected by
teaching). As the set value increases, wider range
of colors is covered.
Range of detection
color for rotation
correction*
1
COLOR% R
0 – 25
(1)
Sets the range of the color for the rotation
correction (margin against the color selected by
teaching). As the set value increases, a wider
range of colors is covered.
Darkness
correction
factor*
1
★
DARK CMP
0 – 31
(27)
Sets the ratio to correct the darkness of colors.No
correction is made with “
0
”, and maximum
correction is made with “
31
” (amplifying black
and converting it to other color).As the set
value increases, dark color tends to be a noise
element; while as the set value decreases, sensor
is affected by disturbance light more.
*1:Set value changes when the bank is switched.
★
:Patent is pending.