51
CHANGING SET VALUE
5
In order to confirm the movement
of the position correction, display
TRNS
by pressing
several
times.
A work in orange is displayed with its position
corrected to the center (registered position).
6
Press
for 3 seconds or
more.
The set value change screen is displayed
and the set value is displayed in red.
7
Decrease the set value by pressing
. (POSIT%X=5)
The work in orange returns to the right since
the maximum value for the horizontal position
correction is limited to 5 (pixels).
8
Press
for 3 seconds or more.
The set value is entered and the set value
reference screen is restored.
Pressing
will restore the set value
reference screen, canceling the revision
to the set value.
9
Press
.
The standard screen is restored.
5
Ramco Innovations
www.optex-ramco.com
phone 800-280-6933