background image

 

Safety Instructions 

 

 

 

 

 

 

 

 

 

 

 

 

 

The optical devices used in this equipment are Hazard Level 1M. As required by IEC60825-1, the installer is responsible for insuring that the 
label depicted below is present in the restricted locations where this equipment is installed.  

 

This assembly contains parts sensitive to damage by electrostatic discharge (ESD). Use ESD precautionary procedures 
when touching, removing, or inserting parts or assemblies.  

 
 
The chassis into which this unit is installed must be housed in a properly rated NEMA enclosure.  

 
 
When this unit is operated in extremely elevated temperature conditions, it is possible for internal and external metal 
surfaces to become extremely hot. Care should be taken to insure this unit is installed in a restricted area where only 
properly trained service personnel have access to the unit.  

 

 

 

The safety information contained in this section, and on other pages of this manual, must be observed whenever this unit is operated, 
serviced, or repaired. Failure to comply with any precaution, warning, or instruction noted in the manual is in violation of the standards of 
design, manufacture, and intended use of the unit. TKH Security Solutions USA assumes no liability for the customer’s failure to comply 
with any of these safety requirements. 

 

RM-1

 

 

LASER RADIATION  

DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS (MAGNIFIERS)  

CLASS 1M LASER PRODUCT 

 

CAUTION:  

DISCONNECTED OPTICAL CONNECTORS MAY EMIT OPTICAL ENERGY.  

DO NOT VIEW BEAM WITH OPTICAL INSTRUMENTS (MAGNIFIERS) 

 

This product contains Class 1M lasers or LEDs.

   

• Class 1M laser product according to IEC60825-1:1993+A1+A2 
• 

CAUTION: Use of controls or adjustments or procedures other than those specified herein may result in hazardous radiation exposure.          

• Precautions should be taken to prevent exposure to optical radiation when the unit is removed from its enclosure or when fiber is  
  disconnected from the unit. 
•Laser radiation may be present on a fiber connection to this unit even when the power has been removed from the unit. 
•This unit is intended for installation in locations where only trained service personnel have access to the fiber connections.

  

•The locations of all optical connections are listed in the Connection Locations and Function section of this manual. 
•Optical outputs and wavelengths are listed in the Specifications section of this manual.   

 

 

Hazard Level 1M 

The border shall be black and 
the background shall be yellow 

 

 

Содержание 9482-DR

Страница 1: ...R Four Channel Digital Video Transmitter and Receiver Cards with Up the Coax Control Data 9482D cards transport four video signals with up the coax control data along with two duplex data channels and...

Страница 2: ......

Страница 3: ...curit 7 Fiber Information 8 Functional Description 9 9482DT Indicator and Connector Locations Functions and Settings 10 9482DR Indicator and Connector Locations Functions and Settings 12 Set Up and O...

Страница 4: ...anufacture and intended use of the unit TKH Security Solutions USA assumes no liability for the customer s failure to comply with any of these safety requirements RM 1 LASER RADIATION DO NOT VIEW DIRE...

Страница 5: ...est ndares de dise o fabricaci n y el uso destinado a la unidad TKH Security Solutions USA no asume ninguna responsabilidad si el cliente no cumple con alguno de estos reequisitos de seguridad RM 1 R...

Страница 6: ...ions und Herstellungsstandards und erfolgt im gegensatz zum vorgesehenen Verwendungszweck dieser Einheit TKH Security Solutions USA bernimmt keine Haftung f r das Verabs umnis des Kunden diese Sicherh...

Страница 7: ...cation et indication d usage de l appareil TKH Security Solutions USA n est pas responsable du non respect de ces consignes de s curit par le client RM 1 RAYONNEMENT LASER NE PAS REGARDER DIRECTEMENT...

Страница 8: ...Caution Pure isopropanol is very flammable b Use lintless tissues to clean fibers c Clean the fiber with a folded tissue moistened with the propanol pulling the connector tip across the tissue then t...

Страница 9: ...eams for the video and the data The video stream signal is converted back into four video signals that are output at the BNC connectors The data stream is demultiplexed and routed to the two data port...

Страница 10: ...Indicates that the local unit has synchronized to the signal from the remote unit and the remote unit is reporting it has synchronized to the local unit 2 VIDEO INPUT PRESENT INDICATORS 1 2 3 AND 4 Ea...

Страница 11: ...DUPLEX HIGH SPEED PORT CONNECTOR This RJ45 connector provides the connections for the high speed port Refer to the Set Up section of this manual for instructions on programming and connecting this po...

Страница 12: ...dicates that the local unit has synchronized to the signal from the remote unit and the remote unit is reporting it has synchronized to the local unit 2 TX VIDEO INPUT PRESENT INDICATORS 1 2 3 AND 4 E...

Страница 13: ...7 DUPLEX HIGH SPEED PORT CONNECTOR This RJ45 connector provides the connections for the high speed port Refer to the Set Up section of this manual for instructions on programming and connecting this p...

Страница 14: ...le 1 below show how the dipswitch is configured for the user programmable data port Additional figures show how the electrical connections are made for the data ports The set up switch is identical on...

Страница 15: ...ould be required RS232 RS232 is a point to point or one to one connection allowing only one transmitter and one receiver per electrical link Care should be taken to insure that the Tx or transmitting...

Страница 16: ...G AND SHIELDS The common ground signal ground on the TKH Security USA equipment is also chassis ground The ground connection is required on both ends of an electrical connection when RS232 is used Bot...

Страница 17: ...17 FIGURE 6 DATA PORT 2 RS232 CONNECTIONS FIGURE 7 DATA PORT 2 RS422 OR RS485 4 WIRE CONNECTIONS...

Страница 18: ...18 FIGURE 8 DATA PORT 2 RS488 2 WIRE DUPLEX CONNECTIONS FIGURE 9 DATA PORT 2 MANCHESTER BI PHASE CONNECTIONS...

Страница 19: ...19 FIGURE 10 RS422 AND RS485 TERMINATION EXAMPLES...

Страница 20: ...20 FIGURE 11 RS422 TERMINATION EXAMPLES FIGURE 12 RS422 TERMINATION EXAMPLES...

Страница 21: ...details on the availability of options for this port The RJ45 Cat5 cable connected to this port should not exceed 1 3 meters 4 feet in length Connection information for these ports is provided in the...

Страница 22: ...l Number 3 Serial Number 4 Time 5 Wavelength 6 Revision Number 7 Chronometer Value Cumulative Hours of Operation 8 Reset Cycles Cumulative Number of Power Cycles 9 Firmware Revision 10 Laser LED Drive...

Страница 23: ...eceiver Optical Budget dB Rcvr Out Pwr Txmtr Input Sens 19 19 24 Estimated Distance Km 50 mm1 2 1 6 N A N A Estimated Distance Km 62 5 mm1 2 N A 1 6 N A Estimated Distance Km 09 mm1 2 N A N A 1 6 1 Di...

Страница 24: ...ackplane Mechanical Physical Dimensions in inches 6 1 H x 1 6 W x 8 6 D Environmental Operating Temperature 40C to 74 C Storage Temperature 55 C to 85 C Relative Humidity 0 to 95 noncondensing The cha...

Страница 25: ......

Страница 26: ...ouda The Netherlands Telephone 31 182 592 333 Fax 31 182 592 123 E mail sales nl tkhsecurity com TKH Security Solutions USA 12920 Cloverleaf Center Drive Germantown Maryland 20874 USA Telephone 1 301...