4
Safety Instructions
The optical devices used in this equipment are Hazard Level 1M. As required by IEC60825-1, the installer is responsible for insuring that the
label depicted below is present in the restricted locations where this equipment is installed.
This assembly contains parts sensitive to damage by electrostatic discharge (ESD). Use ESD precautionary procedures
when touching, removing, or inserting parts or assemblies.
The chassis into which this unit is installed must be housed in a properly rated NEMA enclosure.
When this unit is operated in extremely elevated temperature conditions, it is possible for internal and external metal
surfaces to become extremely hot. Care should be taken to insure this unit is installed in a restricted area where only
properly trained service personnel have access to the unit.
The safety information contained in this section, and on other pages of this manual, must be observed whenever this unit is operated,
serviced, or repaired. Failure to comply with any precaution, warning, or instruction noted in the manual is in violation of the standards of
design, manufacture, and intended use of the unit. TKH Security Solutions USA assumes no liability for the customer’s failure to comply
with any of these safety requirements.
RM-1
LASER RADIATION
DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS (MAGNIFIERS)
CLASS 1M LASER PRODUCT
CAUTION:
DISCONNECTED OPTICAL CONNECTORS MAY EMIT OPTICAL ENERGY.
DO NOT VIEW BEAM WITH OPTICAL INSTRUMENTS (MAGNIFIERS)
This product contains Class 1M lasers or LEDs.
• Class 1M laser product according to IEC60825-1:1993+A1+A2
•
CAUTION: Use of controls or adjustments or procedures other than those specified herein may result in hazardous radiation exposure.
• Precautions should be taken to prevent exposure to optical radiation when the unit is removed from its enclosure or when fiber is
disconnected from the unit.
•Laser radiation may be present on a fiber connection to this unit even when the power has been removed from the unit.
•This unit is intended for installation in locations where only trained service personnel have access to the fiber connections.
•The locations of all optical connections are listed in the Connection Locations and Function section of this manual.
•Optical outputs and wavelengths are listed in the Specifications section of this manual.
Hazard Level 1M
The border shall be black and
the background shall be yellow
Содержание 9482-DR
Страница 2: ......
Страница 17: ...17 FIGURE 6 DATA PORT 2 RS232 CONNECTIONS FIGURE 7 DATA PORT 2 RS422 OR RS485 4 WIRE CONNECTIONS...
Страница 18: ...18 FIGURE 8 DATA PORT 2 RS488 2 WIRE DUPLEX CONNECTIONS FIGURE 9 DATA PORT 2 MANCHESTER BI PHASE CONNECTIONS...
Страница 19: ...19 FIGURE 10 RS422 AND RS485 TERMINATION EXAMPLES...
Страница 20: ...20 FIGURE 11 RS422 TERMINATION EXAMPLES FIGURE 12 RS422 TERMINATION EXAMPLES...
Страница 25: ......