10
9482DT Indicator and Connector Locations,Functions, and
Settings
F
IGURE
1
1. STATUS INDICATORS
This multicolor LED provides status information about the link as follows:
OFF: Indicates no power is applied to the card.
Red
(No Sync): Indicates the local unit is not receiving sufficient optical signal from the remote unit
or the local demux circuitry is not able to synchronize to the incoming signal.
Yellow
(Sync, No Loop): Indicates that the local unit is synchronized to the remote unit, but the
remote unit is reporting it has not synchronized to the local unit.
Green
(Sync, Loop – Normal Operation): Indicates that the local unit has synchronized to the signal
from the remote unit and the remote unit is reporting it has synchronized to the local unit.
2. VIDEO INPUT PRESENT INDICATORS 1, 2, 3, AND 4
Each of these indicators will illuminate
green
when a video signal is present on the respective video
input connector.
3. DATA ACTIVE INDICATORS 1, 2, 3, AND 4
Each of these indicators will illuminate
green
when there is PTZ command output signal activity present
on the respective video input connector.
4. DUPLEX DATA CONNECTOR
This RJ45 connector contains the connections for the two built-in data ports, a fixed RS232 data port,
and a user-programmable RS232, RS485, RS422, or Manchester data port. Refer to the Set Up section of
this manual for instructions on programming and connecting these ports.
Содержание 9482-DR
Страница 2: ......
Страница 17: ...17 FIGURE 6 DATA PORT 2 RS232 CONNECTIONS FIGURE 7 DATA PORT 2 RS422 OR RS485 4 WIRE CONNECTIONS...
Страница 18: ...18 FIGURE 8 DATA PORT 2 RS488 2 WIRE DUPLEX CONNECTIONS FIGURE 9 DATA PORT 2 MANCHESTER BI PHASE CONNECTIONS...
Страница 19: ...19 FIGURE 10 RS422 AND RS485 TERMINATION EXAMPLES...
Страница 20: ...20 FIGURE 11 RS422 TERMINATION EXAMPLES FIGURE 12 RS422 TERMINATION EXAMPLES...
Страница 25: ......