en
Circulating air C-version, activated carbon in
tower, see separate manual "activated carbon".
Exchange and cleaning of the
grease filter
Fire risk!
The performance of the extractor
hood is affected by containing fat remains
and therefore the fire risk increases.
To
prevent a fire risk please clean the metal
filter regularly.
By models with a pane beneath the filter
(“Perimeter Extraction”) the pane has to be
removed at first.
For this s
wing at first the
small front glass pane with one hand
upwards and then take the filter out at its
grip.
The metal grease filter is fixed by a
magnet.
The installation is made in reverse
order.
The metal grease filter is to be cleaned at
best in a dishwasher or in hot soapy water.
Aggressive cleaners should not be used.
Caution: Do not wash grease filter together
with silver cutlery in the dishwasher! This
leads to destruction of the grease filter
(galvanic element, not a complaint claim)
The guarantee can´t be applied if a
discolouring on the filter is a result of using
an aggressive dishwashing liquid. Please
avoid temperatures over 55 degrees.
Attention: do not use 3-phase-cleaners or
clean the filter in a commercial dishwasher.
The use of aggressive cleaners like fuel,
acetone, trichlorethylene destroys the filter!
Reinstate the
metal filter after the cleaning.
By models using the “Perimeter Extraction”
method the pane has to be brought
afterwards in its original position. Therefore
please press the pane with both hands
upwards to a certain extent (lock in of the
pane).
Exchange of the active carbon
filter
( only extractor hoods with circular air )
Active carbon filters bundle up odorous
substances which are contained in the
kitchen fume. According to the strain of work
this filter has to be exchanged after 3-6
months.
The active carbon filter is often mounted on
a frame sitting below the ventilator module.
For the exchange of the active carbon filter
turn both black toggle screws around 90
degrees. After flapping down the pane and
taking out the frame the filter can be changed
easily. The installation is made in reverse
order.
By some extractor hoods the active carbon
filter is directly mounted on the metal filter.
After the removal of the metal filters take
the charcoal filter out and substitute it by a
new one. Important: please do not clean
the active carbon filter with water or any other
liquid.
28