1 Upper chimney
2 Lower chimney
3 Switch panel
4 Grease filter
5 Lighting LED 2700 - 6500K
6 Extractor hood
7 IR remote control
en
Product description
Operating variants:
Control panel: 7-point control
The switch panel consists according to the
model type of five or seven key buttons.
Power of the supercharger
The first four buttons control the power of
the supercharger.
Button „1“
= low performance of the
supercharger
Button „2“
= middle performance of the
supercharger
Button „3“
= high performance of the
supercharger
Button „Int“
= intensive level
extractor hood automatically switches back
after 3 min. from the intensive level to level
3 (high performance of the supercharger).
Automatic Cool Down Period
The automatic cool down period is activated
by pressing the button with the clock symbol.
The extractor hood switches back one level
every 5 minutes from the current level and
switches after a maximum of 15 minutes.
finally off.
Lighting
Press the button with the light symbol to
turn on the illumination. The illumination is
turned off by pressing the button again. The
illumination is dimmed by pressing and
holding the button for a longer period.
Brightness is raised again by another
long press of the button.
By pressing and holding the automatic
overrun button, the colour temp. can be
adjusted. (2700 to 6500K) of the
illumination.
Clean Grease Filter Alert
When the clean grease filter alert lights up
(right button), the filter must be cleaned. Af-
ter cleaning the filter, press and hold the
right button for at least 5 seconds. The alert
red ligh
t will turn off. The clean grease filter
alert will be activated after a maximum of
15 operating hours
( Display and reset only possible when
switched on ! )
int
Press any button to switch on the extractor
hood. The hood is switched off by pressing
the back-lighted keys once more. The
Reset: Clean Grease Filter Alert
Button min. 5 sec. pressures to
a
red LED
goes off !
25