On-Net Surveillance Systems, Inc.
NetDVMS 6.5e
Administration
70
Add New Event Window (Devices With One Input Event)
The
Add New Event
window (for devices capable of handling one input event only) lets you specify the settings for an
input event on devices capable of handling one input event only.
Access:
You access the
Add New Event
window (for devices capable of handling one input event only) by
selecting the required device and clicking the
Add new event...
button in the
I/O Setup
window
. Note that this only
applies when the selected device is capable of handling a single input event only. Some devices are capable of
handling several input events, in which case a different window, the
Multiple Input Events
window
, will open when the
Add new event...
button is clicked.
Note:
Before you specify input events for a device, verify that sensor operation is recognized by the device. Most
devices are capable of showing this in their configuration interfaces, or via CGI script commands. Also check the
NetDVMS release note to verify that input-controlled operations are supported for the device and firmware used.
•
Add New Event Window's Fields
The
Add New Event
window (for devices capable of handling one input event only) contains the following
fields:
Field, Check Box
Description
External sensor
connected to
Read-only field, displaying the name of the device on which the input event
is defined.
Sensor
connected
through
Lets you select which of the device's input ports the sensor used for the
input event is connected to.
Event occurs
when input goes
Lets you select whether input event should be triggered when the signal on
the input sensor rises or falls:
•
Low:
Trigger input event when the signal on the sensor is falling
•
High:
Trigger input event when the signal on the sensor is rising
For exact information about what constitutes a falling and a rising signal
respectively, refer to documentation for the sensor and device in question.
External event
name
Lets you specify a name for the input event.
Note:
Event names must not contain the following characters: < > & ' " \ / : *
? | [ ]
Note:
Some camera devices only support event names of a certain length
and/or with a certain structure. Refer to the camera's documentation for
exact details.
Send e-mail if
this event
occurs
Select check box to send an e-mail alert when the input occurs.
Note:
In order to be able to use e-mail alerts, the e-mail alert feature must
have been set up in the
E-Mail setup
window
.