I. System Start-Up Information
2
V - Systems Owner’s Manual O.A.S. 2008
c
1. Read the installation and maintenance instructions as well as the recommended safety practices in this
manual
2. Install ductwork completely before operating collector:
A.) Seal ductwork with silicone sealant or duct tape.
B.) Have dust bin in place and sealed.
Caution
The Direct Drive Fan / Blower makes the system top heavy! Use extreme care when setting the unit
up! It is recommended that at least two people lift the system up.
Do NOT over tighten bolt on Fan
/ Blower to Cyclone body connection ring! Use a Nylock nut and regular hex nut. If bolt is
over torqued it can break, causing Fan / Blower to disconnect.
Warning
Do not operate Fan / Blower unless Fan Housing is attached to Cyclone body and Dust Drum is in
place. Dust Drum and Cyclone must be in place and sealed or motor will overheat!
Warning
Check amperage draw on motor with all gates open. Current draw should not exceed maximum
motor amperage as stated on motor plate. (OAS is not responsible for damage to motors caused by
improper installation, wiring or failure to follow these directions.)