background image

Rev: 05/17/2021

Doc. #ZBM000104

Appearance may vary slightly

U.S. Patent: #8491685,  

#8496719, #7247180

OWNER’S MANUAL 

High Vacuum 

Dust Collector

with SMART Boost 

and Air Lock

5 HP

# XXS050334

Summary of Contents for 7247180

Page 1: ...Rev 05 17 2021 Doc ZBM000104 Appearance may vary slightly U S Patent 8491685 8496719 7247180 OWNER S MANUAL High Vacuum Dust Collector with SMART Boost and Air Lock 5 HP XXS050334...

Page 2: ......

Page 3: ...ontents System Start Up Information 2 System Specifications 4 System Dimensions 5 System Contents 6 Assembly Instructions 8 Maintenance 18 Troubleshooting 19 F A Q 20 Recommended Accessories 22 Warran...

Page 4: ...17 of an inch in certain concentration ranges when ignited can deflagrate burn quickly An ignition source such as a spark or ember can ignite a dust mixture resulting in an expanding flame front whic...

Page 5: ...information on portable extinguishers can be found in NFPA 10 Standard for Portable Fire Extinguishers 11 Be especially careful with sanding units They can produce concentrations of dust in the combu...

Page 6: ...A 15A On Off Switch Remote Starter with Push button On Off Switch and RF Keyfob Power Cord 10 ft Power Connector Wire Recommended Circuit Size 30A Recommended Circuit Size HACR Sound Emission 84 85 dB...

Page 7: ...mm 106 1 4 2 699 mm X mm 57 1 2 1 461 mm 8 203 mm 56 1 422 mm 60 9 16 1538 mm Nominal dimensions shown using Height Position 3 Telescoping Stand can be adjusted to accommodate smaller waste container...

Page 8: ...155 5 16 18 x 1 Flange Bolt 15 O3 AFW180000 5 16 Flat Washer 39 O4 AFS015700 3 8 16 x 1 1 4 Hex Head Bolt 3 O5 AFW190000 3 8 Flat Washer 20 O6 AFT000004 3 8 Whiz Lock Nut 10 O7 AFB155190 5 16 18 x 1 H...

Page 9: ...neida air com 8 8 7 7 8 12 12 8 8 8 8 4 4 4 24 System Contents Continued A B D E F F C O2 O2 O3 O3 O3 O5 O8 O6 O7 O9 G Q J L I M4 M1 M4 M3 N P M2 M6 M2 K H O1 Note Comes attached to the Motor Assembly...

Page 10: ...led at 45 degree increments Some orientations are not possible Assembly Instructions Tip Aim the dust collector s outlet away from the area where people tend to work to reduce noise Filter will obstru...

Page 11: ...ly to the top rim of the Barrel C outside of the bolt holes FIG 2b c Apply to the Fan Housing s B outlet inside the bolt holes FIG 2c d Apply to the top of the Fan Housing B outside the bolt holes FIG...

Page 12: ...he stand using twelve Hex Head Bolts O7 twenty four Flat Washers O3 and twelve Whiz Lock Nuts O8 FIG 4 5 Lift the Fan Housing B onto the Barrel C making sure it is oriented so that the molded UP text...

Page 13: ...les with the motor plate holes following the orientation shown in FIG 6a Secure the Motor Assembly to the Fan Housing using seven Flange Bolts O2 and seven Flat Washers O3 FIG 6b Note The eighth hole...

Page 14: ...but do not over compress the gasket 8 Open two 8 Duct Clamps G and slip them over the Plenum Extension F FIG 8a Mate the Plenum Extension to the 8 Outlet Adapter E then the Elbow H and close the Clamp...

Page 15: ...t through the clear lining and reinforcing wire FIG 10a Attach both pieces of 7 Diameter Flex Hose to the 8x7x7 Pants Wye I and secure them in place with the 6 8 Hose Clamps J Repeat the process to at...

Page 16: ...ctions Continued 11 Insert the Drop In Silencer M1 into the top of each Filter N FIG 11 FIG 12 FIG 11 12 Attach each Filter N to the Dual Filter Plate L with four J Bolts M4 four Flat Washers M3 and f...

Page 17: ...the filter attach the ring terminal on the braided ground wire from the Motor Assembly A to a J bolt M4 on the Dual Filter Plate L under the Thumb Nut M2 then attach the alligator clip to the filter s...

Page 18: ...of your choice to temporarily secure the starter to the wall FIG 16 To permanently secure the starter to the wall proceed to Step 17 16 Oneida Air Systems Wall Adhesive 15 Assemble the Airlock Q FIG...

Page 19: ...ugh the four mounting holes FIG 17b b Use appropriate fasteners for the wall type you are installing your system onto c Drill into the wall at the marked locations d Secure the starter to the wall 18...

Page 20: ...bient temperature of 109 F 43 C would qualify as the Severe service condition and should instead be lubricated every 2 750 hours A right angled grease coupler will be needed for this operation 1 Motor...

Page 21: ...s a sealant 3 Check for air leaks between collector and Air Lock 4 Close all unused blast gates 5 Check for a restricted pipe too small a hood port or too small a branch line 6 Be sure that your filte...

Page 22: ...ge from 106 1012 Ohms How often should I clean the dust collector s cartridge filter This can vary widely depending on how often your dust collector is used and what kind of dusts it s exposed to but...

Page 23: ...w end Should I remove the internal drop in foam silencer from my filter before installing the Stacking Sound Filter No you do not need to remove the internal foam filter This Drop in Silencer can be u...

Page 24: ...5HP Transfer Blower Kit BSK050199 Single Phase BSK050399 Three Phase Pneumatic conveyance system for use with Air Lock valves to transfer bulk waste away from the dust collector Blower features an in...

Page 25: ...abrasion resistant anti static polyurethane Reinforced with steel wire helix for heavy duty usage Transparent hose makes it easy to spot and clear potential blockages 7 Deluxe Ductwork Starter Kit KDZ...

Page 26: ...n effort to achieve better quality products SAFETY WARNING PLEASE READ Before Purchasing or Installing a dust collection system the buyer is cautioned to do so in accordance with prescribed Federal St...

Page 27: ...25 oneida air com Notes...

Page 28: ...ess of where you purchased your system if you have any questions or issues with missing damaged parts please call Oneida Air Systems first to let us help resolve your problem We fully stand behind the...

Reviews: